ACC SHELL
DOCS-IF-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
-- do not import BITS,
Unsigned32,
Integer32,
Counter32,
TimeTicks,
IpAddress,
transmission
FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
MacAddress,
RowStatus,
TruthValue,
TimeInterval,
TimeStamp
FROM SNMPv2-TC
OBJECT-GROUP,
MODULE-COMPLIANCE
FROM SNMPv2-CONF
ifIndex, InterfaceIndexOrZero
FROM IF-MIB;
docsIfMib MODULE-IDENTITY
LAST-UPDATED "9908190000Z" -- August 19, 1999
ORGANIZATION "IETF IPCDN Working Group"
CONTACT-INFO
" Michael StJohns
Postal: @Home Network
425 Broadway
Redwood City, CA
U.S.A.
Phone: +1 650 569 5368
E-mail: stjohns@corp.home.net"
DESCRIPTION
"This is the MIB Module for MCNS/DOCSIS compliant Radio
Frequency (RF) interfaces in Cable Modems (CM) and
Cable Modem Termination Systems (CMTS)."
REVISION "9908190000Z"
DESCRIPTION
"Initial Version, published as RFC 2670.
Modified by Mike StJohns to fix problems identified by
the first pass of the MIB doctor. Of special note,
docsIfRangingResp and docsIfCmtsInsertionInterval were
obsoleted and replaced by other objects with the same
functionality, but more appropriate SYNTAX."
::= { transmission 127 }
-- Textual Conventions
TenthdBmV ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-1"
STATUS current
DESCRIPTION
"This data type represents power levels that are normally
expressed in dBmV. Units are in tenths of a dBmV;
for example, 5.1 dBmV will be represented as 51."
SYNTAX Integer32
TenthdB ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-1"
STATUS current
DESCRIPTION
"This data type represents power levels that are normally
expressed in dB. Units are in tenths of a dB;
for example, 5.1 dB will be represented as 51."
SYNTAX Integer32
docsIfMibObjects OBJECT IDENTIFIER ::= { docsIfMib 1 }
docsIfBaseObjects OBJECT IDENTIFIER ::= { docsIfMibObjects 1 }
docsIfCmObjects OBJECT IDENTIFIER ::= { docsIfMibObjects 2 }
docsIfCmtsObjects OBJECT IDENTIFIER ::= { docsIfMibObjects 3 }
--
-- BASE GROUP
--
--
-- The following table is implemented on both the Cable Modem (CM)
-- and the Cable Modem Termination System (CMTS).
--
docsIfDownstreamChannelTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfDownstreamChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes the attributes of downstream
channels (frequency bands)."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Table 4-12 and Table 4-13."
::= { docsIfBaseObjects 1 }
docsIfDownstreamChannelEntry OBJECT-TYPE
SYNTAX DocsIfDownstreamChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry provides a list of attributes for a single
Downstream channel.
An entry in this table exists for each ifEntry with an
ifType of docsCableDownstream(128)."
INDEX { ifIndex }
::= { docsIfDownstreamChannelTable 1 }
DocsIfDownstreamChannelEntry ::= SEQUENCE {
docsIfDownChannelId Integer32,
docsIfDownChannelFrequency Integer32,
docsIfDownChannelWidth Integer32,
docsIfDownChannelModulation INTEGER,
docsIfDownChannelInterleave INTEGER,
docsIfDownChannelPower TenthdBmV
}
docsIfDownChannelId OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Cable Modem Termination System (CMTS) identification
of the downstream channel within this particular MAC
interface. If the interface is down, the object returns
the most current value. If the downstream channel ID is
unknown, this object returns a value of 0."
::= { docsIfDownstreamChannelEntry 1 }
docsIfDownChannelFrequency OBJECT-TYPE
SYNTAX Integer32 (0..1000000000)
UNITS "hertz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The center of the downstream frequency associated with
this channel. This object will return the current tuner
frequency. If a CMTS provides IF output, this object
will return 0, unless this CMTS is in control of the
final downstream RF frequency. See the associated
compliance object for a description of valid frequencies
that may be written to this object."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Section 4.3.3."
::= { docsIfDownstreamChannelEntry 2 }
docsIfDownChannelWidth OBJECT-TYPE
SYNTAX Integer32 (0..16000000)
UNITS "hertz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The bandwidth of this downstream channel. Most
implementations are expected to support a channel width
of 6 MHz (North America) and/or 8 MHz (Europe). See the
associated compliance object for a description of the
valid channel widths for this object."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Table 4-12 and Table 4-13."
::= { docsIfDownstreamChannelEntry 3 }
docsIfDownChannelModulation OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2),
qam64(3),
qam256(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The modulation type associated with this downstream
channel. If the interface is down, this object either
returns the configured value (CMTS), the most current
value (CM), or the value of unknown(1). See the
associated conformance object for write conditions and
limitations. See the reference for specifics on the
modulation profiles implied by qam64 and qam256."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Section 3.6.2."
::= { docsIfDownstreamChannelEntry 4 }
docsIfDownChannelInterleave OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
other(2),
taps8Increment16(3),
taps16Increment8(4),
taps32Increment4(5),
taps64Increment2(6),
taps128Increment1(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Forward Error Correction (FEC) interleaving used
for this downstream channel.
Values are defined as follows:
taps8Increment16(3): protection 5.9/4.1 usec,
latency .22/.15 msec
taps16Increment8(4): protection 12/8.2 usec,
latency .48/.33 msec
taps32Increment4(5): protection 24/16 usec,
latency .98/.68 msec
taps64Increment2(6): protection 47/33 usec,
latency 2/1.4 msec
taps128Increment1(7): protection 95/66 usec,
latency 4/2.8 msec
If the interface is down, this object either returns
the configured value (CMTS), the most current value (CM),
or the value of unknown(1).
The value of other(2) is returned if the interleave
is known but not defined in the above list.
See the associated conformance object for write
conditions and limitations. See the reference for the FEC
configuration described by the setting of this object."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Section 4.3.2."
::= { docsIfDownstreamChannelEntry 5 }
docsIfDownChannelPower OBJECT-TYPE
SYNTAX TenthdBmV
UNITS "dBmV"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"At the CMTS, the operational transmit power. At the CM,
the received power level. May be set to zero at the CM
if power level measurement is not supported.
If the interface is down, this object either returns
the configured value (CMTS), the most current value (CM)
or the value of 0. See the associated conformance object
for write conditions and limitations. See the reference
for recommended and required power levels."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Table 4-12 and Table 4-13."
::= { docsIfDownstreamChannelEntry 6 }
--
-- The following table is implemented on both the CM and the CMTS.
-- For the CM, only attached channels appear in the table. For the
-- CM, this table is read only as well.
--
docsIfUpstreamChannelTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfUpstreamChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes the attributes of attached upstream
channels (frequency bands)."
::= { docsIfBaseObjects 2 }
docsIfUpstreamChannelEntry OBJECT-TYPE
SYNTAX DocsIfUpstreamChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of attributes for a single upstream channel.
An entry in this table exists for each ifEntry with an
ifType of docsCableUpstream(129)."
INDEX { ifIndex }
::= { docsIfUpstreamChannelTable 1 }
DocsIfUpstreamChannelEntry ::= SEQUENCE {
docsIfUpChannelId Integer32,
docsIfUpChannelFrequency Integer32,
docsIfUpChannelWidth Integer32,
docsIfUpChannelModulationProfile Unsigned32,
docsIfUpChannelSlotSize Unsigned32,
docsIfUpChannelTxTimingOffset Unsigned32,
docsIfUpChannelRangingBackoffStart Integer32,
docsIfUpChannelRangingBackoffEnd Integer32,
docsIfUpChannelTxBackoffStart Integer32,
docsIfUpChannelTxBackoffEnd Integer32
}
docsIfUpChannelId OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The CMTS identification of the upstream channel."
::= { docsIfUpstreamChannelEntry 1 }
docsIfUpChannelFrequency OBJECT-TYPE
SYNTAX Integer32 (0..1000000000)
UNITS "hertz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The center of the frequency band associated with this
upstream channel. This object returns 0 if the frequency
is undefined or unknown. Minimum permitted upstream
frequency is 5,000,000 Hz for current technology. See
the associated conformance object for write conditions
and limitations."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Table 2-2."
::= { docsIfUpstreamChannelEntry 2 }
docsIfUpChannelWidth OBJECT-TYPE
SYNTAX Integer32 (0..20000000)
UNITS "hertz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The bandwidth of this upstream channel. This object
returns 0 if the channel width is undefined or unknown.
Minimum permitted channel width is 200,000 Hz currently.
See the associated conformance object for write conditions
and limitations."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Table 4-3."
::= { docsIfUpstreamChannelEntry 3 }
docsIfUpChannelModulationProfile OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An entry identical to the docsIfModIndex in the
docsIfCmtsModulationTable that describes this channel.
This channel is further instantiated there by a grouping
of interval usage codes which together fully describe the
channel modulation. This object returns 0 if the
docsIfCmtsModulationTable entry does not exist or
docsIfCmtsModulationTable is empty. See
the associated conformance object for write conditions
and limitations."
::= { docsIfUpstreamChannelEntry 4 }
docsIfUpChannelSlotSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of 6.25 microsecond ticks in each upstream mini-
slot. Returns zero if the value is undefined or unknown.
See the associated conformance object for write
conditions and limitations."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Section 6.1.2.4."
::= { docsIfUpstreamChannelEntry 5 }
docsIfUpChannelTxTimingOffset OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A measure of the current round trip time at the CM, or the
maximum round trip time seen by the CMTS. Used for timing
of CM upstream transmissions to ensure synchronized
arrivals at the CMTS. Units are in terms of
(6.25 microseconds/64)."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Section 6.5."
::= { docsIfUpstreamChannelEntry 6 }
docsIfUpChannelRangingBackoffStart OBJECT-TYPE
SYNTAX Integer32 (0..16)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The initial random backoff window to use when retrying
Ranging Requests. Expressed as a power of 2. A value of 16
at the CMTS indicates that a proprietary adaptive retry
mechanism is to be used. See the associated conformance
object for write conditions and limitations."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Section 6.4.4."
::= { docsIfUpstreamChannelEntry 7 }
docsIfUpChannelRangingBackoffEnd OBJECT-TYPE
SYNTAX Integer32 (0..16)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The final random backoff window to use when retrying
Ranging Requests. Expressed as a power of 2. A value of 16
at the CMTS indicates that a proprietary adaptive retry
mechanism is to be used. See the associated conformance
object for write conditions and limitations."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Section 6.4.4."
::= { docsIfUpstreamChannelEntry 8 }
docsIfUpChannelTxBackoffStart OBJECT-TYPE
SYNTAX Integer32 (0..16)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The initial random backoff window to use when retrying
transmissions. Expressed as a power of 2. A value of 16
at the CMTS indicates that a proprietary adaptive retry
mechanism is to be used. See the associated conformance
object for write conditions and limitations."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Section 6.4.4."
::= { docsIfUpstreamChannelEntry 9 }
docsIfUpChannelTxBackoffEnd OBJECT-TYPE
SYNTAX Integer32 (0..16)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The final random backoff window to use when retrying
transmissions. Expressed as a power of 2. A value of 16
at the CMTS indicates that a proprietary adaptive retry
mechanism is to be used. See the associated conformance
object for write conditions and limitations."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Section 6.4.4."
::= { docsIfUpstreamChannelEntry 10 }
-- The following table describes the attributes of each class of
-- service. The entries in this table are referenced from the
-- docsIfServiceEntries. They exist as a separate table in order to
-- reduce redundant information in docsIfServiceTable.
--
-- This table is implemented at both the CM and the CMTS.
-- The CM need only maintain entries for the classes of service
-- referenced by its docsIfServiceTable.
--
docsIfQosProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfQosProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes the attributes for each class of service."
::= { docsIfBaseObjects 3 }
docsIfQosProfileEntry OBJECT-TYPE
SYNTAX DocsIfQosProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes the attributes for a single class of service.
If implemented as read-create in the Cable Modem
Termination System, creation of entries in this table is
controlled by the value of docsIfCmtsQosProfilePermissions.
If implemented as read-only, entries are created based
on information in REG-REQ MAC messages received from
Cable Modems (Cable Modem Termination System
implementation), or based on information extracted from
the TFTP option file (Cable Modem implementation).
In the Cable Modem Termination system, read-only entries
are removed if no longer referenced by
docsIfCmtsServiceTable.
An entry in this table must not be removed while it is
referenced by an entry in docsIfCmServiceTable (Cable Modem)
or docsIfCmtsServiceTable (Cable Modem Termination System).
An entry in this table should not be changeable while
it is referenced by an entry in docsIfCmtsServiceTable.
If this table is created automatically, there should only
be a single entry for each Class of Service. Multiple
entries with the same Class of Service parameters are not
recommended."
INDEX { docsIfQosProfIndex }
::= { docsIfQosProfileTable 1 }
DocsIfQosProfileEntry ::= SEQUENCE {
docsIfQosProfIndex Integer32,
docsIfQosProfPriority Integer32,
docsIfQosProfMaxUpBandwidth Integer32,
docsIfQosProfGuarUpBandwidth Integer32,
docsIfQosProfMaxDownBandwidth Integer32,
docsIfQosProfMaxTxBurst Integer32,
docsIfQosProfBaselinePrivacy TruthValue,
docsIfQosProfStatus RowStatus
}
docsIfQosProfIndex OBJECT-TYPE
SYNTAX Integer32 (1..16383)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index value which uniquely identifies an entry
in the docsIfQosProfileTable."
::= { docsIfQosProfileEntry 1 }
docsIfQosProfPriority OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A relative priority assigned to this service when
allocating bandwidth. Zero indicates lowest priority;
and seven indicates highest priority.
Interpretation of priority is device-specific.
MUST NOT be changed while this row is active."
DEFVAL { 0 }
::= { docsIfQosProfileEntry 2 }
docsIfQosProfMaxUpBandwidth OBJECT-TYPE
SYNTAX Integer32 (0..100000000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum upstream bandwidth, in bits per second,
allowed for a service with this service class.
Zero if there is no restriction of upstream bandwidth.
MUST NOT be changed while this row is active."
DEFVAL { 0 }
::= { docsIfQosProfileEntry 3 }
docsIfQosProfGuarUpBandwidth OBJECT-TYPE
SYNTAX Integer32 (0..100000000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Minimum guaranteed upstream bandwidth, in bits per second,
allowed for a service with this service class.
MUST NOT be changed while this row is active."
DEFVAL { 0 }
::= { docsIfQosProfileEntry 4 }
docsIfQosProfMaxDownBandwidth OBJECT-TYPE
SYNTAX Integer32 (0..100000000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum downstream bandwidth, in bits per second,
allowed for a service with this service class.
Zero if there is no restriction of downstream bandwidth.
MUST NOT be changed while this row is active."
DEFVAL { 0 }
::= { docsIfQosProfileEntry 5 }
docsIfQosProfMaxTxBurst OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum number of mini-slots that may be requested
for a single upstream transmission.
A value of zero means there is no limit.
MUST NOT be changed while this row is active."
DEFVAL { 0 }
::= { docsIfQosProfileEntry 6 }
docsIfQosProfBaselinePrivacy OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates whether Baseline Privacy is enabled for this
service class.
MUST NOT be changed while this row is active."
DEFVAL { false }
::= { docsIfQosProfileEntry 7 }
docsIfQosProfStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is object is to used to create or delete rows in
this table. This object MUST NOT be changed from active
while the row is referenced by the any entry in either
docsIfCmServiceTable (on the CM), or the
docsIfCmtsServiceTable (on the CMTS)."
::= { docsIfQosProfileEntry 8 }
docsIfSignalQualityTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfSignalQualityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"At the CM, describes the PHY signal quality of downstream
channels. At the CMTS, describes the PHY signal quality of
upstream channels. At the CMTS, this table may exclude
contention intervals."
::= { docsIfBaseObjects 4 }
docsIfSignalQualityEntry OBJECT-TYPE
SYNTAX DocsIfSignalQualityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"At the CM, describes the PHY characteristics of a
downstream channel. At the CMTS, describes the PHY signal
quality of an upstream channel.
An entry in this table exists for each ifEntry with an
ifType of docsCableUpstream(129) for Cable Modem Termination
Systems and docsCableDownstream(128) for Cable Modems."
INDEX { ifIndex }
::= { docsIfSignalQualityTable 1 }
DocsIfSignalQualityEntry ::= SEQUENCE {
docsIfSigQIncludesContention TruthValue,
docsIfSigQUnerroreds Counter32,
docsIfSigQCorrecteds Counter32,
docsIfSigQUncorrectables Counter32,
docsIfSigQSignalNoise TenthdB,
docsIfSigQMicroreflections Integer32,
docsIfSigQEqualizationData OCTET STRING
}
docsIfSigQIncludesContention OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"true(1) if this CMTS includes contention intervals in
the counters in this table. Always false(2) for CMs."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 6.4.4"
::= { docsIfSignalQualityEntry 1 }
docsIfSigQUnerroreds OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Codewords received on this channel without error.
This includes all codewords, whether or not they
were part of frames destined for this device."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 4.2.3 and 4.3.6"
::= { docsIfSignalQualityEntry 2 }
docsIfSigQCorrecteds OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Codewords received on this channel with correctable
errors. This includes all codewords, whether or not
they were part of frames destined for this device."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 4.2.3 and 4.3.6"
::= { docsIfSignalQualityEntry 3 }
docsIfSigQUncorrectables OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Codewords received on this channel with uncorrectable
errors. This includes all codewords, whether or not
they were part of frames destined for this device."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 4.2.3 and 4.3.6"
::= { docsIfSignalQualityEntry 4 }
docsIfSigQSignalNoise OBJECT-TYPE
SYNTAX TenthdB
UNITS "dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal/Noise ratio as perceived for this channel.
At the CM, describes the Signal/Noise of the downstream
channel. At the CMTS, describes the average Signal/Noise
of the upstream channel."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Table 2-1 and 2-2"
::= { docsIfSignalQualityEntry 5 }
docsIfSigQMicroreflections OBJECT-TYPE
SYNTAX Integer32 (0..255)
UNITS "dBc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total microreflections including in-channel response
as perceived on this interface, measured in dBc below
the signal level.
This object is not assumed to return an absolutely
accurate value, but should give a rough indication
of microreflections received on this interface.
It is up to the implementor to provide information
as accurate as possible."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Table 2-1 and 2-2"
::= { docsIfSignalQualityEntry 6 }
docsIfSigQEqualizationData OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"At the CM, returns the equalization data for the downstream
channel. At the CMTS, returns the average equalization
data for the upstream channel. Returns an empty string
if the value is unknown or if there is no equalization
data available or defined."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Figure 6-23."
::= { docsIfSignalQualityEntry 7 }
--
-- CABLE MODEM GROUP
--
-- #######
--
-- The CM MAC Table
--
docsIfCmMacTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfCmMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes the attributes of each CM MAC interface,
extending the information available from ifEntry."
::= { docsIfCmObjects 1 }
docsIfCmMacEntry OBJECT-TYPE
SYNTAX DocsIfCmMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing objects describing attributes of
each MAC entry, extending the information in ifEntry.
An entry in this table exists for each ifEntry with an
ifType of docsCableMaclayer(127)."
INDEX { ifIndex }
::= { docsIfCmMacTable 1 }
DocsIfCmMacEntry ::= SEQUENCE {
docsIfCmCmtsAddress MacAddress,
docsIfCmCapabilities BITS,
docsIfCmRangingRespTimeout TimeTicks,
docsIfCmRangingTimeout TimeInterval
}
docsIfCmCmtsAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifies the CMTS that is believed to control this MAC
domain. At the CM, this will be the source address from
SYNC, MAP, and other MAC-layer messages. If the CMTS is
unknown, returns 00-00-00-00-00-00."
::= { docsIfCmMacEntry 1 }
docsIfCmCapabilities OBJECT-TYPE
SYNTAX BITS {
atmCells(0),
concatenation(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifies the capabilities of the MAC implementation
at this interface. Note that packet transmission is
always supported. Therefore, there is no specific bit
required to explicitely indicate this capability."
::= { docsIfCmMacEntry 2 }
-- This object has been obsoleted and replaced by
-- docsIfCmRangingTimeout to correct the typing to TimeInterval. New
-- implementations of the MIB should use docsIfCmRangingTimeout instead.
docsIfCmRangingRespTimeout OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Waiting time for a Ranging Response packet."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Figure 7-6 and 7-7, timer T3."
DEFVAL { 20 }
::= { docsIfCmMacEntry 3 }
docsIfCmRangingTimeout OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Waiting time for a Ranging Response packet."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Figure 7-6 and 7-7, timer T3."
DEFVAL { 20 }
::= { docsIfCmMacEntry 4 }
--
-- CM status table.
-- This table is implemented only at the CM.
--
docsIfCmStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfCmStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table maintains a number of status objects
and counters for Cable Modems."
::= { docsIfCmObjects 2 }
docsIfCmStatusEntry OBJECT-TYPE
SYNTAX DocsIfCmStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of status objects and counters for a single MAC
layer instance in a Cable Modem.
An entry in this table exists for each ifEntry with an
ifType of docsCableMaclayer(127)."
INDEX { ifIndex }
::= { docsIfCmStatusTable 1 }
DocsIfCmStatusEntry ::= SEQUENCE {
docsIfCmStatusValue INTEGER,
docsIfCmStatusCode OCTET STRING,
docsIfCmStatusTxPower TenthdBmV,
docsIfCmStatusResets Counter32,
docsIfCmStatusLostSyncs Counter32,
docsIfCmStatusInvalidMaps Counter32,
docsIfCmStatusInvalidUcds Counter32,
-- docsIfCmStatusInvalidRangingResp Counter32,
docsIfCmStatusInvalidRangingResponses Counter32,
-- docsIfCmStatusInvalidRegistrationResp Counter32,
docsIfCmStatusInvalidRegistrationResponses Counter32,
docsIfCmStatusT1Timeouts Counter32,
docsIfCmStatusT2Timeouts Counter32,
docsIfCmStatusT3Timeouts Counter32,
docsIfCmStatusT4Timeouts Counter32,
docsIfCmStatusRangingAborteds Counter32
}
docsIfCmStatusValue OBJECT-TYPE
SYNTAX INTEGER {
other(1),
notReady(2),
notSynchronized(3),
phySynchronized(4),
usParametersAcquired(5),
rangingComplete(6),
ipComplete(7),
todEstablished(8),
securityEstablished(9),
paramTransferComplete(10),
registrationComplete(11),
operational(12),
accessDenied(13)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Cable Modem connectivity state, as specified
in the RF Interface Specification."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Chapter 7.2."
::= { docsIfCmStatusEntry 1 }
docsIfCmStatusCode OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status code for this Cable Modem as defined in the
RF Interface Specification. The status code consists
of a single character indicating error groups, followed
by a two- or three-digit number indicating the status
condition."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Cable Modem status codes."
::= { docsIfCmStatusEntry 2 }
docsIfCmStatusTxPower OBJECT-TYPE
SYNTAX TenthdBmV
UNITS "dBmV"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational transmit power for the attached upstream
channel."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 4.2.8."
::= { docsIfCmStatusEntry 3 }
docsIfCmStatusResets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times the CM reset or initialized
this interface."
::= { docsIfCmStatusEntry 4 }
docsIfCmStatusLostSyncs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times the CM lost synchronization with
the downstream channel."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 6.5."
::= { docsIfCmStatusEntry 5 }
docsIfCmStatusInvalidMaps OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times the CM received invalid MAP messages."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 6.3.2.3 and 6.4.2."
::= { docsIfCmStatusEntry 6 }
docsIfCmStatusInvalidUcds OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times the CM received invalid UCD messages."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 6.3.2.2."
::= { docsIfCmStatusEntry 7 }
-- docsIfCmStatusInvalidRangingResp replaced for Counter32
-- naming requirements
docsIfCmStatusInvalidRangingResponses OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times the CM received invalid ranging response
messages."
::= { docsIfCmStatusEntry 8 }
-- docsIfCmStatusInvalidRegistrationResp replaced for
-- Counter32 naming requirements
docsIfCmStatusInvalidRegistrationResponses OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times the CM received invalid registration
response messages."
::= { docsIfCmStatusEntry 9 }
docsIfCmStatusT1Timeouts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times counter T1 expired in the CM."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Figure 7-3."
::= { docsIfCmStatusEntry 10 }
docsIfCmStatusT2Timeouts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times counter T2 expired in the CM."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Figure 7-6."
::= { docsIfCmStatusEntry 11 }
docsIfCmStatusT3Timeouts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times counter T3 expired in the CM."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Figure 7-6 and 7-7."
::= { docsIfCmStatusEntry 12 }
docsIfCmStatusT4Timeouts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times counter T4 expired in the CM."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Figure 7-7."
::= { docsIfCmStatusEntry 13 }
docsIfCmStatusRangingAborteds OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times the ranging process was aborted
by the CMTS."
::= { docsIfCmStatusEntry 14 }
--
-- The Cable Modem Service Table
--
docsIfCmServiceTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfCmServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes the attributes of each upstream service queue
on a CM."
::= { docsIfCmObjects 3 }
docsIfCmServiceEntry OBJECT-TYPE
SYNTAX DocsIfCmServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes the attributes of an upstream bandwidth service
queue.
An entry in this table exists for each Service ID.
The primary index is an ifIndex with an ifType of
docsCableMaclayer(127)."
INDEX { ifIndex, docsIfCmServiceId }
::= { docsIfCmServiceTable 1 }
DocsIfCmServiceEntry ::= SEQUENCE {
docsIfCmServiceId Integer32,
docsIfCmServiceQosProfile Integer32,
docsIfCmServiceTxSlotsImmed Counter32,
docsIfCmServiceTxSlotsDed Counter32,
docsIfCmServiceTxRetries Counter32,
-- docsIfCmServiceTxExceeded Counter32,
docsIfCmServiceTxExceededs Counter32,
docsIfCmServiceRqRetries Counter32,
-- docsIfCmServiceRqExceeded Counter32
docsIfCmServiceRqExceededs Counter32
}
docsIfCmServiceId OBJECT-TYPE
SYNTAX Integer32 (1..16383)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identifies a service queue for upstream bandwidth. The
attributes of this service queue are shared between the
CM and the CMTS. The CMTS allocates upstream bandwidth
to this service queue based on requests from the CM and
on the class of service associated with this queue."
::= { docsIfCmServiceEntry 1 }
docsIfCmServiceQosProfile OBJECT-TYPE
SYNTAX Integer32 (0..16383)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index in docsIfQosProfileTable describing the quality
of service attributes associated with this particular
service. If no associated entry in docsIfQosProfileTable
exists, this object returns a value of zero."
::= { docsIfCmServiceEntry 2 }
docsIfCmServiceTxSlotsImmed OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of upstream mini-slots which have been used to
transmit data PDUs in immediate (contention) mode. This
includes only those PDUs which are presumed to have
arrived at the headend (i.e., those which were explicitly
acknowledged.) It does not include retransmission attempts
or mini-slots used by Requests."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 6.4."
::= { docsIfCmServiceEntry 3 }
docsIfCmServiceTxSlotsDed OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of upstream mini-slots which have been used to
transmit data PDUs in dedicated mode (i.e., as a result
of a unicast Data Grant)."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 6.4."
::= { docsIfCmServiceEntry 4 }
docsIfCmServiceTxRetries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of attempts to transmit data PDUs containing
requests for acknowledgment which did not result in
acknowledgment."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 6.4."
::= { docsIfCmServiceEntry 5 }
-- docsIfCmServiceTxExceeded renamed for Counter32 naming requirements
docsIfCmServiceTxExceededs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of data PDUs transmission failures due to
excessive retries without acknowledgment."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 6.4."
::= { docsIfCmServiceEntry 6 }
docsIfCmServiceRqRetries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of attempts to transmit bandwidth requests
which did not result in acknowledgment."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 6.4."
::= { docsIfCmServiceEntry 7 }
-- docsIfCmServiceRqExceeded renamed for Counter 32 naming
-- requirements
docsIfCmServiceRqExceededs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of requests for bandwidth which failed due to
excessive retries without acknowledgment."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 6.4."
::= { docsIfCmServiceEntry 8 }
--
-- CMTS GROUP
--
--
-- The CMTS MAC Table
--
docsIfCmtsMacTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfCmtsMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes the attributes of each CMTS MAC interface,
extending the information available from ifEntry.
Mandatory for all CMTS devices."
::= { docsIfCmtsObjects 1 }
docsIfCmtsMacEntry OBJECT-TYPE
SYNTAX DocsIfCmtsMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing objects describing attributes of each
MAC entry, extending the information in ifEntry.
An entry in this table exists for each ifEntry with an
ifType of docsCableMaclayer(127)."
INDEX { ifIndex }
::= { docsIfCmtsMacTable 1 }
DocsIfCmtsMacEntry ::= SEQUENCE {
docsIfCmtsCapabilities BITS,
docsIfCmtsSyncInterval Integer32,
docsIfCmtsUcdInterval Integer32,
docsIfCmtsMaxServiceIds Integer32,
docsIfCmtsInsertionInterval TimeTicks, -- Obsolete
docsIfCmtsInvitedRangingAttempts Integer32,
docsIfCmtsInsertInterval TimeInterval
}
docsIfCmtsCapabilities OBJECT-TYPE
SYNTAX BITS {
atmCells(0),
concatenation(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifies the capabilities of the CMTS MAC
implementation at this interface. Note that packet
transmission is always supported. Therefore, there
is no specific bit required to explicitely indicate
this capability."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Chapter 6."
::= { docsIfCmtsMacEntry 1 }
docsIfCmtsSyncInterval OBJECT-TYPE
SYNTAX Integer32 (1..200)
UNITS "Milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interval between CMTS transmission of successive SYNC
messages at this interface."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Section 6.5 and Appendix B."
::= { docsIfCmtsMacEntry 2 }
docsIfCmtsUcdInterval OBJECT-TYPE
SYNTAX Integer32 (1..2000)
UNITS "Milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interval between CMTS transmission of successive
Upstream Channel Descriptor messages for each upstream
channel at this interface."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Section 6.5 and Appendix B."
::= { docsIfCmtsMacEntry 3 }
docsIfCmtsMaxServiceIds OBJECT-TYPE
SYNTAX Integer32 (1..16383)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of service IDs that may be
simultaneously active."
::= { docsIfCmtsMacEntry 4 }
-- This object has been obsoleted and replaced by
-- docsIfCmtsInsertInterval to fix a SYNTAX typing problem. New
-- implementations of this MIB should use that object instead.
docsIfCmtsInsertionInterval OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"The amount of time to elapse between each broadcast
station maintenance grant. Broadcast station maintenance
grants are used to allow new cable modems to join the
network. Zero indicates that a vendor-specific algorithm
is used instead of a fixed time. Maximum amount of time
permitted by the specification is 2 seconds."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Appendix B, Ranging Interval."
::= { docsIfCmtsMacEntry 5 }
docsIfCmtsInvitedRangingAttempts OBJECT-TYPE
SYNTAX Integer32 (0..1024)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of attempts to make on invitations
for ranging requests. A value of zero means the system
should attempt to range forever."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 7.2.5 and Appendix B."
::= { docsIfCmtsMacEntry 6 }
docsIfCmtsInsertInterval OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The amount of time to elapse between each broadcast
station maintenance grant. Broadcast station maintenance
grants are used to allow new cable modems to join the
network. Zero indicates that a vendor-specific algorithm
is used instead of a fixed time. Maximum amount of time
permitted by the specification is 2 seconds."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Appendix B."
::= { docsIfCmtsMacEntry 7 }
--
--
-- CMTS status table.
--
docsIfCmtsStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfCmtsStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"For the MAC layer, this group maintains a number of
status objects and counters."
::= { docsIfCmtsObjects 2 }
docsIfCmtsStatusEntry OBJECT-TYPE
SYNTAX DocsIfCmtsStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Status entry for a single MAC layer.
An entry in this table exists for each ifEntry with an
ifType of docsCableMaclayer(127)."
INDEX { ifIndex }
::= { docsIfCmtsStatusTable 1 }
DocsIfCmtsStatusEntry ::= SEQUENCE {
docsIfCmtsStatusInvalidRangeReqs Counter32,
docsIfCmtsStatusRangingAborteds Counter32,
docsIfCmtsStatusInvalidRegReqs Counter32,
docsIfCmtsStatusFailedRegReqs Counter32,
docsIfCmtsStatusInvalidDataReqs Counter32,
docsIfCmtsStatusT5Timeouts Counter32
}
docsIfCmtsStatusInvalidRangeReqs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object counts invalid RNG-REQ messages received on
this interface."
::= { docsIfCmtsStatusEntry 1 }
docsIfCmtsStatusRangingAborteds OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object counts ranging attempts that were explicitely
aborted by the CMTS."
::= { docsIfCmtsStatusEntry 2 }
docsIfCmtsStatusInvalidRegReqs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object counts invalid REG-REQ messages received on
this interface."
::= { docsIfCmtsStatusEntry 3 }
docsIfCmtsStatusFailedRegReqs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object counts failed registration attempts, i.e.,
authentication failures and class of service failures,
on this interface."
::= { docsIfCmtsStatusEntry 4 }
docsIfCmtsStatusInvalidDataReqs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object counts invalid data request messages
received on this interface."
::= { docsIfCmtsStatusEntry 5 }
docsIfCmtsStatusT5Timeouts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object counts the number of times counter T5
expired on this interface."
::= { docsIfCmtsStatusEntry 6 }
--
-- CM status table (within CMTS).
-- This table is implemented only at the CMTS.
-- It contains per CM status information available in the CMTS.
--
docsIfCmtsCmStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfCmtsCmStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of objects in the CMTS, maintained for each
Cable Modem connected to this CMTS."
::= { docsIfCmtsObjects 3 }
docsIfCmtsCmStatusEntry OBJECT-TYPE
SYNTAX DocsIfCmtsCmStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Status information for a single Cable Modem.
An entry in this table exists for each Cable Modem
that is connected to the CMTS implementing this table."
INDEX { docsIfCmtsCmStatusIndex }
::= { docsIfCmtsCmStatusTable 1 }
DocsIfCmtsCmStatusEntry ::= SEQUENCE {
docsIfCmtsCmStatusIndex Integer32,
docsIfCmtsCmStatusMacAddress MacAddress,
docsIfCmtsCmStatusIpAddress IpAddress,
docsIfCmtsCmStatusDownChannelIfIndex InterfaceIndexOrZero,
docsIfCmtsCmStatusUpChannelIfIndex InterfaceIndexOrZero,
docsIfCmtsCmStatusRxPower TenthdBmV,
docsIfCmtsCmStatusTimingOffset Unsigned32,
docsIfCmtsCmStatusEqualizationData OCTET STRING,
docsIfCmtsCmStatusValue INTEGER,
docsIfCmtsCmStatusUnerroreds Counter32,
docsIfCmtsCmStatusCorrecteds Counter32,
docsIfCmtsCmStatusUncorrectables Counter32,
docsIfCmtsCmStatusSignalNoise TenthdB,
docsIfCmtsCmStatusMicroreflections Integer32
}
docsIfCmtsCmStatusIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index value to uniquely identify an entry in this table.
For an individual Cable Modem, this index value should
not change during CMTS uptime."
::= { docsIfCmtsCmStatusEntry 1 }
docsIfCmtsCmStatusMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address of this Cable Modem. If the Cable Modem has
multiple MAC addresses, this is the MAC address associated
with the Cable interface."
::= { docsIfCmtsCmStatusEntry 2 }
docsIfCmtsCmStatusIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP address of this Cable Modem. If the Cable Modem has no
IP address assigned, or the IP address is unknown, this
object returns a value of 0.0.0.0. If the Cable Modem has
multiple IP addresses, this object returns the IP address
associated with the Cable interface."
::= { docsIfCmtsCmStatusEntry 3 }
docsIfCmtsCmStatusDownChannelIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IfIndex of the downstream channel this CM is connected
to. If the downstream channel is unknown, this object
returns a value of zero."
::= { docsIfCmtsCmStatusEntry 4 }
docsIfCmtsCmStatusUpChannelIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IfIndex of the upstream channel this CM is connected
to. If the upstream channel is unknown, this object
returns a value of zero."
::= { docsIfCmtsCmStatusEntry 5 }
docsIfCmtsCmStatusRxPower OBJECT-TYPE
SYNTAX TenthdBmV
UNITS "dBmV"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The receive power as percieved for upstream data from
this Cable Modem.
If the receive power is unknown, this object returns
a value of zero."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Table 4-13."
::= { docsIfCmtsCmStatusEntry 6 }
docsIfCmtsCmStatusTimingOffset OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A measure of the current round trip time for this CM.
Used for timing of CM upstream transmissions to ensure
synchronized arrivals at the CMTS. Units are in terms
of (6.25 microseconds/64). Returns zero if the value
is unknown."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Section 6.5."
::= { docsIfCmtsCmStatusEntry 7 }
docsIfCmtsCmStatusEqualizationData OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Equalization data for this CM. Returns an empty string
if the value is unknown or if there is no equalization
data available or defined."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Figure 6-23."
::= { docsIfCmtsCmStatusEntry 8 }
docsIfCmtsCmStatusValue OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ranging(2),
rangingAborted(3),
rangingComplete(4),
ipComplete(5),
registrationComplete(6),
accessDenied(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Cable Modem connectivity state, as specified
in the RF Interface Specification. Returned status
information is the CM status as assumed by the CMTS,
and indicates the following events:
other(1)
Any state other than below.
ranging(2)
The CMTS has received an Initial Ranging Request
message from the CM, and the ranging process is not
yet complete.
rangingAborted(3)
The CMTS has sent a Ranging Abort message to the CM.
rangingComplete(4)
The CMTS has sent a Ranging Complete message to the CM.
ipComplete(5)
The CMTS has received a DHCP reply message and forwarded
it to the CM.
registrationComplete(6)
The CMTS has sent a Registration Response mesage to
the CM.
accessDenied(7)
The CMTS has sent a Registration Aborted message
to the CM.
The CMTS only needs to report states it is able to detect."
REFERENCE
"DOCSIS Radio Frequency Interface Specification,
Chapter 7.2."
::= { docsIfCmtsCmStatusEntry 9 }
docsIfCmtsCmStatusUnerroreds OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Codewords received without error from this Cable Modem."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 4.2.3"
::= { docsIfCmtsCmStatusEntry 10 }
docsIfCmtsCmStatusCorrecteds OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Codewords received with correctable errors from this
Cable Modem."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 4.2.3"
::= { docsIfCmtsCmStatusEntry 11 }
docsIfCmtsCmStatusUncorrectables OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Codewords received with uncorrectable errors from this
Cable Modem."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 4.2.3"
::= { docsIfCmtsCmStatusEntry 12 }
docsIfCmtsCmStatusSignalNoise OBJECT-TYPE
SYNTAX TenthdB
UNITS "dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal/Noise ratio as perceived for upstream data from
this Cable Modem.
If the Signal/Noise is unknown, this object returns
a value of zero."
::= { docsIfCmtsCmStatusEntry 13 }
docsIfCmtsCmStatusMicroreflections OBJECT-TYPE
SYNTAX Integer32 (0..255)
UNITS "dBc"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total microreflections including in-channel response
as perceived on this interface, measured in dBc below
the signal level.
This object is not assumed to return an absolutely
accurate value, but should give a rough indication
of microreflections received on this interface.
It is up to the implementor to provide information
as accurate as possible."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Table 2-1 and 2-2"
::= { docsIfCmtsCmStatusEntry 14 }
--
-- The CMTS Service Table.
--
docsIfCmtsServiceTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfCmtsServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes the attributes of upstream service queues
in a Cable Modem Termination System."
::= { docsIfCmtsObjects 4 }
docsIfCmtsServiceEntry OBJECT-TYPE
SYNTAX DocsIfCmtsServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes the attributes of a single upstream bandwidth
service queue.
Entries in this table exist for each ifEntry with an
ifType of docsCableMaclayer(127), and for each service
queue (Service ID) within this MAC layer.
Entries in this table are created with the creation of
individual Service IDs by the MAC layer and removed
when a Service ID is removed."
INDEX { ifIndex, docsIfCmtsServiceId }
::= { docsIfCmtsServiceTable 1 }
DocsIfCmtsServiceEntry ::= SEQUENCE {
docsIfCmtsServiceId Integer32,
docsIfCmtsServiceCmStatusIndex Integer32,
docsIfCmtsServiceAdminStatus INTEGER,
docsIfCmtsServiceQosProfile Integer32,
docsIfCmtsServiceCreateTime TimeStamp,
docsIfCmtsServiceInOctets Counter32,
docsIfCmtsServiceInPackets Counter32
}
docsIfCmtsServiceId OBJECT-TYPE
SYNTAX Integer32 (1..16383)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identifies a service queue for upstream bandwidth. The
attributes of this service queue are shared between the
Cable Modem and the Cable Modem Termination System.
The CMTS allocates upstream bandwidth to this service
queue based on requests from the CM and on the class of
service associated with this queue."
::= { docsIfCmtsServiceEntry 1 }
docsIfCmtsServiceCmStatusIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Pointer to an entry in docsIfCmtsCmStatusTable identifying
the Cable Modem using this Service Queue. If multiple
Cable Modems are using this Service Queue, the value of
this object is zero."
::= { docsIfCmtsServiceEntry 2 }
docsIfCmtsServiceAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
destroyed(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Allows a service class for a particular modem to be
suppressed, (re-)enabled, or deleted altogether."
::= { docsIfCmtsServiceEntry 3 }
docsIfCmtsServiceQosProfile OBJECT-TYPE
SYNTAX Integer32 (0..16383)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index in docsIfQosProfileTable describing the quality
of service attributes associated with this particular
service. If no associated docsIfQosProfileTable entry
exists, this object returns a value of zero."
::= { docsIfCmtsServiceEntry 4 }
docsIfCmtsServiceCreateTime OBJECT-TYPE
-- SYNTAX TimeTicks
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when this entry was created."
::= { docsIfCmtsServiceEntry 5 }
docsIfCmtsServiceInOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The cumulative number of Packet Data octets received
on this Service ID. The count does not include the
size of the Cable MAC header"
::= { docsIfCmtsServiceEntry 6 }
docsIfCmtsServiceInPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The cumulative number of Packet Data packets received
on this Service ID."
::= { docsIfCmtsServiceEntry 7 }
--
-- The following table provides upstream channel modulation profiles.
-- Entries in this table can be
-- re-used by one or more upstream channels. An upstream channel will
-- have a modulation profile
-- for each value of docsIfModIntervalUsageCode.
--
docsIfCmtsModulationTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfCmtsModulationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes a modulation profile associated with one or more
upstream channels."
::= { docsIfCmtsObjects 5 }
docsIfCmtsModulationEntry OBJECT-TYPE
SYNTAX DocsIfCmtsModulationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Describes a modulation profile for an Interval Usage Code
for one or more upstream channels.
Entries in this table are created by the operator. Initial
default entries may be created at system initialization
time. No individual objects have to be specified in order
to create an entry in this table.
Note that some objects do not have DEFVALs, but do have
calculated defaults and need not be specified during row
creation.
There is no restriction on the changing of values in this
table while their associated rows are active."
INDEX { docsIfCmtsModIndex, docsIfCmtsModIntervalUsageCode }
::= { docsIfCmtsModulationTable 1 }
DocsIfCmtsModulationEntry ::= SEQUENCE {
docsIfCmtsModIndex Integer32,
docsIfCmtsModIntervalUsageCode INTEGER,
docsIfCmtsModControl RowStatus,
docsIfCmtsModType INTEGER,
docsIfCmtsModPreambleLen Integer32,
docsIfCmtsModDifferentialEncoding TruthValue,
docsIfCmtsModFECErrorCorrection Integer32,
docsIfCmtsModFECCodewordLength Integer32,
docsIfCmtsModScramblerSeed Integer32,
docsIfCmtsModMaxBurstSize Integer32,
docsIfCmtsModGuardTimeSize Unsigned32,
docsIfCmtsModLastCodewordShortened TruthValue,
docsIfCmtsModScrambler TruthValue
}
docsIfCmtsModIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index into the Channel Modulation table representing
a group of Interval Usage Codes, all associated with the
same channel."
::= { docsIfCmtsModulationEntry 1 }
docsIfCmtsModIntervalUsageCode OBJECT-TYPE
SYNTAX INTEGER {
request(1),
requestData(2),
initialRanging(3),
periodicRanging(4),
shortData(5),
longData(6)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index into the Channel Modulation table which, when
grouped with other Interval Usage Codes, fully
instantiate all modulation sets for a given upstream
channel."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Table 6-16."
::= { docsIfCmtsModulationEntry 2 }
docsIfCmtsModControl OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Controls and reflects the status of rows in this table."
::= { docsIfCmtsModulationEntry 3 }
docsIfCmtsModType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
qpsk(2),
qam16(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The modulation type used on this channel. Returns
other(1) if the modulation type is neither qpsk or
qam16. See the reference for the modulation profiles
implied by qpsk or qam16. See the conformance object for
write conditions and limitations."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 4.2.2."
DEFVAL { qpsk }
::= { docsIfCmtsModulationEntry 4 }
docsIfCmtsModPreambleLen OBJECT-TYPE
SYNTAX Integer32 (0..1024)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The preamble length for this modulation profile in bits.
Default value is the minimum needed by the implementation
at the CMTS for the given modulation profile."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 4.2.5."
::= { docsIfCmtsModulationEntry 5 }
docsIfCmtsModDifferentialEncoding OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies whether or not differential encoding is used
on this channel."
DEFVAL { false }
::= { docsIfCmtsModulationEntry 6 }
docsIfCmtsModFECErrorCorrection OBJECT-TYPE
SYNTAX Integer32 (0..10)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of correctable errored bytes (t) used in
forward error correction code. The value of 0 indicates
no correction is employed. The number of check bytes
appended will be twice this value."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 4.2.3."
DEFVAL { 0 }
::= { docsIfCmtsModulationEntry 7 }
docsIfCmtsModFECCodewordLength OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of data bytes (k) in the forward error
correction codeword.
This object is not used if docsIfCmtsModFECErrorCorrection
is zero."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 4.2.3."
DEFVAL { 32 }
::= { docsIfCmtsModulationEntry 8 }
docsIfCmtsModScramblerSeed OBJECT-TYPE
SYNTAX Integer32 (0..32767)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The 15 bit seed value for the scrambler polynomial."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 4.2.4."
DEFVAL { 0 }
::= { docsIfCmtsModulationEntry 9 }
docsIfCmtsModMaxBurstSize OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The maximum number of mini-slots that can be transmitted
during this channel's burst time. Returns zero if the
burst length is bounded by the allocation MAP rather than
this profile.
Default value is 0 except for shortData, where it is 8."
::= { docsIfCmtsModulationEntry 10 }
docsIfCmtsModGuardTimeSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of symbol-times which must follow the end of
this channel's burst. Default value is the minimum time
needed by the implementation for this modulation profile."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 4.2.7."
::= { docsIfCmtsModulationEntry 11 }
docsIfCmtsModLastCodewordShortened OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates if the last FEC codeword is truncated."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 4.2.10."
DEFVAL { true }
::= { docsIfCmtsModulationEntry 12 }
docsIfCmtsModScrambler OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates if the scrambler is employed."
REFERENCE
"DOCSIS Radio Frequency Interface specification,
Section 4.2.4."
DEFVAL { false }
::= { docsIfCmtsModulationEntry 13 }
docsIfCmtsQosProfilePermissions OBJECT-TYPE
SYNTAX BITS {
createByManagement(0),
updateByManagement(1),
createByModems(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies permitted methods of creating
entries in docsIfQosProfileTable.
CreateByManagement(0) is set if entries can be created
using SNMP. UpdateByManagement(1) is set if updating
entries using SNMP is permitted. CreateByModems(2)
is set if entries can be created based on information
in REG-REQ MAC messages received from Cable Modems.
Information in this object is only applicable if
docsIfQosProfileTable is implemented as read-create.
Otherwise, this object is implemented as read-only
and returns CreateByModems(2).
Either CreateByManagement(0) or CreateByModems(1)
must be set when writing to this object."
::= { docsIfCmtsObjects 6 }
docsIfCmtsMacToCmTable OBJECT-TYPE
SYNTAX SEQUENCE OF DocsIfCmtsMacToCmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is a table to provide a quick access index into the
docsIfCmtsCmStatusTable. There is exactly one row in this
table for each row in the docsIfCmtsCmStatusTable. In
general, the management station should use this table only
to get a pointer into the docsIfCmtsCmStatusTable (which
corresponds to the CM's RF interface MAC address), and
should not iterate (e.g. GetNext through) this table."
::= { docsIfCmtsObjects 7 }
docsIfCmtsMacToCmEntry OBJECT-TYPE
SYNTAX DocsIfCmtsMacToCmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row in the docsIfCmtsMacToCmTable.
An entry in this table exists for each Cable Modem
that is connected to the CMTS implementing this table."
INDEX { docsIfCmtsCmMac }
::= {docsIfCmtsMacToCmTable 1 }
DocsIfCmtsMacToCmEntry ::= SEQUENCE {
docsIfCmtsCmMac MacAddress,
docsIfCmtsCmPtr Integer32
}
docsIfCmtsCmMac OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The RF side MAC address for the referenced CM. (E.g. the
interface on the CM that has docsCableMacLayer(127) as
its ifType."
::= { docsIfCmtsMacToCmEntry 1 }
docsIfCmtsCmPtr OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An row index into docsIfCmtsCmStatusTable. When queried
with the correct instance value (e.g. a CM's MAC address),
returns the index in docsIfCmtsCmStatusTable which
represents that CM."
::= { docsIfCmtsMacToCmEntry 2 }
--
-- notification group is for future extension.
--
docsIfNotification OBJECT IDENTIFIER ::= { docsIfMib 2 }
docsIfConformance OBJECT IDENTIFIER ::= { docsIfMib 3 }
docsIfCompliances OBJECT IDENTIFIER ::= { docsIfConformance 1 }
docsIfGroups OBJECT IDENTIFIER ::= { docsIfConformance 2 }
-- compliance statements
docsIfBasicCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for devices that implement
MCNS/DOCSIS compliant Radio Frequency Interfaces."
MODULE -- docsIfMib
-- unconditionally mandatory groups
MANDATORY-GROUPS {
docsIfBasicGroup
}
-- conditionally mandatory group
GROUP docsIfCmGroup
DESCRIPTION
"This group is implemented only in Cable Modems, not in
Cable Modem Termination Systems."
-- conditionally mandatory group
GROUP docsIfCmtsGroup
DESCRIPTION
"This group is implemented only in Cable Modem Termination
Systems, not in Cable Modems."
OBJECT docsIfDownChannelFrequency
WRITE-SYNTAX Integer32 (54000000..860000000)
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems;
read-only in Cable Modems. The values above are
appropriate for a cable plant using a Sub-Split channel
plan. If DOCSIS is extended to cover other types of
channel plans (and frequency allocations) this object
will be modified accordingly."
OBJECT docsIfDownChannelWidth
WRITE-SYNTAX Integer32 (6000000)
MIN-ACCESS read-only
DESCRIPTION
"It is conformant to implement this object as read-only.
In Cable Modems, this object is always implemented as
read-only. The above value is appropriate for cable
plants running under NTSC (National Television
Standards Committee) standards. If DOCSIS is extended to
work with other standard (e.g. European standards), this
object will be modified accordingly."
OBJECT docsIfDownChannelModulation
WRITE-SYNTAX INTEGER {
qam64 (3),
qam256 (4)
}
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems;
read-only in Cable Modems."
OBJECT docsIfDownChannelInterleave
WRITE-SYNTAX INTEGER {
taps8Increment16(3),
taps16Increment8(4),
taps32Increment4(5),
taps64Increment2(6),
taps128Increment1(7)
}
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems;
read-only in Cable Modems."
OBJECT docsIfDownChannelPower
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems;
read-only in Cable Modems."
OBJECT docsIfUpChannelFrequency
WRITE-SYNTAX Integer32 (5000000..42000000)
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems;
read-only in Cable Modems.The values above are
appropriate for a cable plant using a Sub-Split channel
plan. If DOCSIS is extended to cover other types of
channel plans (and frequency allocations) this object
will be modified accordingly."
OBJECT docsIfUpChannelWidth
WRITE-SYNTAX Integer32 (200000..3200000)
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems;
read-only in Cable Modems.The above value is appropriate
for cable plants running under NTSC (National Television
Standards Committee) standards. If DOCSIS is extended to
work with other standard (e.g. European standards), this
object will be modified accordingly."
OBJECT docsIfUpChannelModulationProfile
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems;
read-only in Cable Modems."
OBJECT docsIfUpChannelSlotSize
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems.
It is compliant to implement this object as read-only
in Cable Modem Termination Systems."
OBJECT docsIfUpChannelRangingBackoffStart
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems;
read-only in Cable Modems."
OBJECT docsIfUpChannelRangingBackoffEnd
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems;
read-only in Cable Modems."
OBJECT docsIfUpChannelTxBackoffStart
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems;
read-only in Cable Modems."
OBJECT docsIfUpChannelTxBackoffEnd
MIN-ACCESS read-only
DESCRIPTION
"Read-write in Cable Modem Termination Systems;
read-only in Cable Modems."
OBJECT docsIfQosProfPriority
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems.
It is compliant to implement this object as read-only
in Cable Modem Termination Systems."
OBJECT docsIfQosProfMaxUpBandwidth
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems.
It is compliant to implement this object as read-only
in Cable Modem Termination Systems."
OBJECT docsIfQosProfGuarUpBandwidth
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems.
It is compliant to implement this object as read-only
in Cable Modem Termination Systems."
OBJECT docsIfQosProfMaxDownBandwidth
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems.
It is compliant to implement this object as read-only
in Cable Modem Termination Systems."
OBJECT docsIfQosProfMaxTxBurst
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems.
It is compliant to implement this object as read-only
in Cable Modem Termination Systems."
OBJECT docsIfQosProfBaselinePrivacy
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems.
It is compliant to implement this object as read-only
in Cable Modem Termination Systems."
OBJECT docsIfQosProfStatus
MIN-ACCESS read-only
DESCRIPTION
"This object is always read-only in Cable Modems.
It is compliant to implement this object as read-only
in Cable Modem Termination Systems."
OBJECT docsIfCmtsServiceAdminStatus
MIN-ACCESS read-only
DESCRIPTION
"It is compliant to implement this object as read-only."
OBJECT docsIfCmtsSyncInterval
MIN-ACCESS read-only
DESCRIPTION
"It is compliant to implement this object as read-only."
OBJECT docsIfCmtsUcdInterval
MIN-ACCESS read-only
DESCRIPTION
"It is compliant to implement this object as read-only."
OBJECT docsIfCmtsInsertInterval
MIN-ACCESS read-only
DESCRIPTION
"It is compliant to implement this object as read-only."
OBJECT docsIfCmtsInvitedRangingAttempts
MIN-ACCESS read-only
DESCRIPTION
"It is compliant to implement this object as read-only."
OBJECT docsIfCmtsQosProfilePermissions
MIN-ACCESS read-only
DESCRIPTION
"It is compliant to implement this object as read-only."
OBJECT docsIfCmtsModType
WRITE-SYNTAX INTEGER {
qpsk (2),
qam16 (3)
}
DESCRIPTION
"Management station may only set 16QAM or QPSK modulation,
but others might be possible based on device configuration."
::= { docsIfCompliances 1 }
docsIfBasicGroup OBJECT-GROUP
OBJECTS {
docsIfDownChannelId,
docsIfDownChannelFrequency,
docsIfDownChannelWidth,
docsIfDownChannelModulation,
docsIfDownChannelInterleave,
docsIfDownChannelPower,
docsIfUpChannelId,
docsIfUpChannelFrequency,
docsIfUpChannelWidth,
docsIfUpChannelModulationProfile,
docsIfUpChannelSlotSize,
docsIfUpChannelTxTimingOffset,
docsIfUpChannelRangingBackoffStart,
docsIfUpChannelRangingBackoffEnd,
docsIfUpChannelTxBackoffStart,
docsIfUpChannelTxBackoffEnd,
docsIfQosProfPriority,
docsIfQosProfMaxUpBandwidth,
docsIfQosProfGuarUpBandwidth,
docsIfQosProfMaxDownBandwidth,
docsIfQosProfMaxTxBurst,
docsIfQosProfBaselinePrivacy,
docsIfQosProfStatus,
docsIfSigQIncludesContention,
docsIfSigQUnerroreds,
docsIfSigQCorrecteds,
docsIfSigQUncorrectables,
docsIfSigQSignalNoise,
docsIfSigQMicroreflections,
docsIfSigQEqualizationData
}
STATUS current
DESCRIPTION
"Group of objects implemented in both Cable Modems and
Cable Modem Termination Systems."
::= { docsIfGroups 1 }
-- The following table was modified to correct naming conventions for
-- Counter32 variables.
docsIfCmGroup OBJECT-GROUP
OBJECTS {
docsIfCmCmtsAddress,
docsIfCmCapabilities,
-- docsIfCmRangingRespTimeout,
docsIfCmRangingTimeout,
docsIfCmStatusValue,
docsIfCmStatusCode,
docsIfCmStatusTxPower,
docsIfCmStatusResets,
docsIfCmStatusLostSyncs,
docsIfCmStatusInvalidMaps,
docsIfCmStatusInvalidUcds,
-- docsIfCmStatusInvalidRangingResp,
docsIfCmStatusInvalidRangingResponses,
-- docsIfCmStatusInvalidRegistrationResp,
docsIfCmStatusInvalidRegistrationResponses,
docsIfCmStatusT1Timeouts,
docsIfCmStatusT2Timeouts,
docsIfCmStatusT3Timeouts,
docsIfCmStatusT4Timeouts,
docsIfCmStatusRangingAborteds,
docsIfCmServiceQosProfile,
docsIfCmServiceTxSlotsImmed,
docsIfCmServiceTxSlotsDed,
docsIfCmServiceTxRetries,
-- docsIfCmServiceTxExceeded,
docsIfCmServiceTxExceededs,
docsIfCmServiceRqRetries,
-- docsIfCmServiceRqExceeded
docsIfCmServiceRqExceededs
}
STATUS current
DESCRIPTION
"Group of objects implemented in Cable Modems."
::= { docsIfGroups 2 }
docsIfCmtsGroup OBJECT-GROUP
OBJECTS {
docsIfCmtsCapabilities,
docsIfCmtsSyncInterval,
docsIfCmtsUcdInterval,
docsIfCmtsMaxServiceIds,
-- docsIfCmtsInsertionInterval,
docsIfCmtsInvitedRangingAttempts,
docsIfCmtsInsertInterval,
docsIfCmtsStatusInvalidRangeReqs,
docsIfCmtsStatusRangingAborteds,
docsIfCmtsStatusInvalidRegReqs,
docsIfCmtsStatusFailedRegReqs,
docsIfCmtsStatusInvalidDataReqs,
docsIfCmtsStatusT5Timeouts,
docsIfCmtsCmStatusMacAddress,
docsIfCmtsCmStatusIpAddress,
docsIfCmtsCmStatusDownChannelIfIndex,
docsIfCmtsCmStatusUpChannelIfIndex,
docsIfCmtsCmStatusRxPower,
docsIfCmtsCmStatusTimingOffset,
docsIfCmtsCmStatusEqualizationData,
docsIfCmtsCmStatusValue,
docsIfCmtsCmStatusUnerroreds,
docsIfCmtsCmStatusCorrecteds,
docsIfCmtsCmStatusUncorrectables,
docsIfCmtsCmStatusSignalNoise,
docsIfCmtsCmStatusMicroreflections,
docsIfCmtsServiceCmStatusIndex,
docsIfCmtsServiceAdminStatus,
docsIfCmtsServiceQosProfile,
docsIfCmtsServiceCreateTime,
docsIfCmtsServiceInOctets,
docsIfCmtsServiceInPackets,
docsIfCmtsModType,
docsIfCmtsModControl,
docsIfCmtsModPreambleLen,
docsIfCmtsModDifferentialEncoding,
docsIfCmtsModFECErrorCorrection,
docsIfCmtsModFECCodewordLength,
docsIfCmtsModScramblerSeed,
docsIfCmtsModMaxBurstSize,
docsIfCmtsModGuardTimeSize,
docsIfCmtsModLastCodewordShortened,
docsIfCmtsModScrambler,
docsIfCmtsQosProfilePermissions,
docsIfCmtsCmPtr
}
STATUS current
DESCRIPTION
"Group of objects implemented in Cable Modem Termination
Systems."
::= { docsIfGroups 3 }
docsIfObsoleteGroup OBJECT-GROUP
OBJECTS {
docsIfCmRangingRespTimeout,
docsIfCmtsInsertionInterval
}
STATUS obsolete
DESCRIPTION
"Group of objects obsoleted."
::= { docsIfGroups 4 }
END
ACC SHELL 2018