ACC SHELL
FRNETSERV-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
NOTIFICATION-TYPE, transmission,
Counter32, Integer32 FROM SNMPv2-SMI
TimeStamp, RowStatus FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP,
NOTIFICATION-GROUP FROM SNMPv2-CONF
InterfaceIndex, ifIndex FROM IF-MIB
SnmpAdminString FROM SNMP-FRAMEWORK-MIB;
frnetservMIB MODULE-IDENTITY
LAST-UPDATED "200009280000Z" -- September 28, 2000
ORGANIZATION "IETF Frame Relay Service MIB Working Group"
CONTACT-INFO
"WG Charter:
http://www.ietf.org/html.charters/frnetmib-charter
WG-email:
frnetmib@sunroof.eng.sun.com
Subscribe:
frnetmib-request@sunroof.eng.sun.com
Email Archive:
ftp://ftp.ietf.org/ietf-mail-archive/frnetmib
Chair: Andy Malis
Vivace Networks, Inc.
Email: Andy.Malis@vivacenetworks.com
WG editor: Kenneth Rehbehn
Megisto Systems, Inc.
Email: krehbehn@megisto.com
Co-author: David Fowler
Syndesis Limited,
EMail: fowler@syndesis.com"
DESCRIPTION
"The MIB module to describe generic objects for
Frame Relay Network Service."
--
-- Revision History
--
REVISION "200009280000Z"
DESCRIPTION
"Published as RFC 2954.
The major new features of this revision include:
o Support for read-write capability to
provision switch components providing service,
o Support for cross-connection via a frame relay
to ATM service interworking function,
o Support for frame relay fragmentation,
o Additional frame counters to track frame
loss.
Refer to Appendix A for a comprehensive list of
changes since RFC 1604."
REVISION "199311161200Z"
DESCRIPTION
"Published as RFC 1604."
::= { transmission 44 }
frnetservObjects
OBJECT IDENTIFIER ::= { frnetservMIB 1 }
frnetservTraps
OBJECT IDENTIFIER ::= { frnetservMIB 2 }
frnetservTrapsPrefix
OBJECT IDENTIFIER ::= { frnetservTraps 0 }
--
-- The Frame Relay Service Logical Port
--
frLportTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrLportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Frame Relay Logical Port Information table is
an interface-specific addendum to the generic
ifTable of the Interface MIB."
::= { frnetservObjects 1 }
frLportEntry OBJECT-TYPE
SYNTAX FrLportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Frame Relay Logical Port
Information table."
INDEX { ifIndex }
::= { frLportTable 1 }
FrLportEntry ::=
SEQUENCE {
frLportNumPlan INTEGER,
frLportContact SnmpAdminString,
frLportLocation SnmpAdminString,
frLportType INTEGER,
frLportAddrDLCILen INTEGER,
frLportVCSigProtocol INTEGER,
frLportVCSigPointer OBJECT IDENTIFIER,
frLportDLCIIndexValue Integer32,
frLportTypeAdmin INTEGER,
frLportVCSigProtocolAdmin INTEGER,
frLportFragControl INTEGER,
frLportFragSize Integer32
}
frLportNumPlan OBJECT-TYPE
SYNTAX INTEGER {
other(1),
e164(2),
x121(3),
none(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the network
address numbering plan for this UNI/NNI logical
port. The network address is the object
ifPhysAddress. The value none(4) implies that
there is no ifPhysAddress. The FRS agent will
return an octet string of zero length for
ifPhysAddress. The value other(1) means that an
address has been assigned to this interface, but
the numbering plan is not enumerated here."
REFERENCE "E.164 [29]
X.121 [30]"
::= { frLportEntry 1 }
frLportContact OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the network
contact for this UNI/NNI logical port."
::= { frLportEntry 2 }
frLportLocation OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the frame
relay network location for this UNI/NNI logical
port."
::= { frLportEntry 3 }
frLportType OBJECT-TYPE
SYNTAX INTEGER {
uni(1),
nni(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the type of
network interface for this logical port."
::= { frLportEntry 4 }
frLportAddrDLCILen OBJECT-TYPE
SYNTAX INTEGER {
twoOctets10Bits(1),
threeOctets10Bits(2),
threeOctets16Bits(3),
fourOctets17Bits(4),
fourOctets23Bits(5)
}
UNITS "Octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the Q.922
Address field length and DLCI length for this
UNI/NNI logical port."
REFERENCE "Q.922 [25]"
::= { frLportEntry 5 }
frLportVCSigProtocol OBJECT-TYPE
SYNTAX INTEGER {
none(1),
lmi(2),
ansiT1617D(3),
ansiT1617B(4),
ccittQ933A(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the Local
In-Channel Signaling Protocol that is used for
this frame relay UNI/NNI logical port.
none(1): Interface does not use a PVC
signaling protocol
lmi(2): Interface operates the Stratacom/
Nortel/DEC Local Management
Interface Specification protocol
ansiT1617D(3): Interface operates the ANSI T1.617
Annex D PVC status protocol
ansiT1617B(4): Interface operates the ANSI
T1.617
Annex B procedures
ccittQ933A(5): Interface operates the ITU Q.933
Annex A PVC status protocol"
REFERENCE "LMI [24]
T1.617 Annex D [17],
Q.933 Annex A [22]"
::= { frLportEntry 6 }
frLportVCSigPointer OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The value of this object is used as a pointer to
the table that contains the Local In-Channel
Signaling Protocol parameters and errors for this
UNI/NNI logical port.
This object has been deprecated to reflect the
fact that the local in-channel signaling
parameters are accessed from a single table
(frMgtVCSigTable) that includes parameters for all
possible signaling protocols. Early design
anticipated multiple tables, one for each
signaling protocol."
::= { frLportEntry 7 }
frLportDLCIIndexValue OBJECT-TYPE
SYNTAX Integer32 (16..4194303)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains a hint to be used for
frPVCEndptDLCIIndex when creating entries in the
frPVCEndptTable. The SYNTAX of this object
matches the SYNTAX of the frPVCEndptDLCIIndex - an
object that is restricted to legal Q.922 DLCI
values for the size of the address field.
The value 0 indicates that no unassigned entries
are available.
To obtain the frPVCEndptDLCIIndex value for a new
entry, the manager issues a management protocol
retrieval operation to obtain the current value of
this object. After each retrieval, the agent must
modify the value to the next unassigned index to
prevent assignment of the same value to multiple
management systems.
A management system should repeat the read to
obtain a new value should an attempt to create the
new row using the previously returned hint fail."
REFERENCE "Q.922 [25]"
::= { frLportEntry 8 }
frLportTypeAdmin OBJECT-TYPE
SYNTAX INTEGER {
uni(1),
nni(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object desired identifies the
type of network interface for this logical port."
::= { frLportEntry 9 }
frLportVCSigProtocolAdmin OBJECT-TYPE
SYNTAX INTEGER {
none(1),
lmi(2),
ansiT1617D(3),
ansiT1617B(4),
ccittQ933A(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the desired
Local In-Channel Signaling Protocol that is used
for this frame relay UNI/NNI logical port. This
value must be made the active protocol as soon as
possible on the device.
Refer to frLportVCSigProtocol for a description of
each signaling protocol choices."
REFERENCE "LMI [24]
T1.617 Annex D [17],
Q.933 Annex A [22]"
::= { frLportEntry 10 }
frLportFragControl OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls the transmission and
reception of fragmentation frames for this UNI or
NNI interface.
on(1) Frames are fragmented using the interface
fragmentation format
Note: The customer side of the interface
must also be configured to fragment
frames.
off(2) Frames are not fragmented using the
interface fragmentation format."
REFERENCE "FRF.12 [21]"
DEFVAL { off }
::= { frLportEntry 11 }
frLportFragSize OBJECT-TYPE
SYNTAX Integer32 (0..4096)
UNITS "Octets"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object is the size in octets of
the maximum size of each fragment to be sent when
fragmenting. This object is only used by the
fragmentation transmitter, and the two sides of
the interface may differ. The fragment size
includes the octets for the frame relay header,
the UI octet, the NLPID, the fragmentation header,
and the fragment payload. If frLportFragControl is
set to off, this value should be zero."
REFERENCE "FRF.12 [21]"
DEFVAL { 0 }
::= { frLportEntry 12 }
--
-- Frame Relay Management VC Signaling
--
frMgtVCSigTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrMgtVCSigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Frame Relay Management VC Signaling
Parameters and Errors table."
::= { frnetservObjects 2 }
frMgtVCSigEntry OBJECT-TYPE
SYNTAX FrMgtVCSigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Frame Relay Management VC
Signaling Parameters Errors table."
INDEX { ifIndex }
::= { frMgtVCSigTable 1 }
FrMgtVCSigEntry ::=
SEQUENCE {
frMgtVCSigProced INTEGER,
frMgtVCSigUserN391 INTEGER,
frMgtVCSigUserN392 INTEGER,
frMgtVCSigUserN393 INTEGER,
frMgtVCSigUserT391 INTEGER,
frMgtVCSigNetN392 INTEGER,
frMgtVCSigNetN393 INTEGER,
frMgtVCSigNetT392 INTEGER,
frMgtVCSigNetnN4 INTEGER,
frMgtVCSigNetnT3 INTEGER,
frMgtVCSigUserLinkRelErrors Counter32,
frMgtVCSigUserProtErrors Counter32,
frMgtVCSigUserChanInactive Counter32,
frMgtVCSigNetLinkRelErrors Counter32,
frMgtVCSigNetProtErrors Counter32,
frMgtVCSigNetChanInactive Counter32,
frMgtVCSigProcedAdmin INTEGER,
frMgtVCSigUserN391Admin INTEGER,
frMgtVCSigUserN392Admin INTEGER,
frMgtVCSigUserN393Admin INTEGER,
frMgtVCSigUserT391Admin INTEGER,
frMgtVCSigNetN392Admin INTEGER,
frMgtVCSigNetN393Admin INTEGER,
frMgtVCSigNetT392Admin INTEGER,
frMgtVCSigNetnT3Admin INTEGER
}
frMgtVCSigProced OBJECT-TYPE
SYNTAX INTEGER {
u2nnet(1),
bidirect(2),
u2nuser(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the local
in-channel signaling procedural role that is used
for this UNI/NNI logical port. Bidirectional
procedures implies that both user-side and
network-side procedural roles are used.
u2nnet(1) Logical port operates user to network
procedure in the role of the network
side
bidirect(2) Logical port operates the
bidirectional procedure (both user
and network side roles)
u2nuser(3) Logical port operates user to network
procedure in the role of the user
side"
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17]"
::= { frMgtVCSigEntry 1 }
frMgtVCSigUserN391 OBJECT-TYPE
SYNTAX INTEGER (1..255)
UNITS "Polls"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the User-side
N391 full status polling cycle value for this
UNI/NNI logical port. If the logical port is not
performing user-side (bidirectional) procedures,
then this object is not instantiated and an
attempt to read will result in the noSuchInstance
exception response."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17]"
DEFVAL { 6 }
::= { frMgtVCSigEntry 2 }
frMgtVCSigUserN392 OBJECT-TYPE
SYNTAX INTEGER (1..10)
UNITS "Events"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the User-side
N392 error threshold value for this UNI/NNI
logical port. If the logical port is not
performing user-side (bidirectional) procedures,
then this object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17]"
DEFVAL { 3 }
::= { frMgtVCSigEntry 3 }
frMgtVCSigUserN393 OBJECT-TYPE
SYNTAX INTEGER (1..10)
UNITS "Events"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the User-side
N393 monitored events count value for this UNI/NNI
logical port. If the logical port is not
performing user-side (bidirectional) procedures,
then this object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17]"
DEFVAL { 4 }
::= { frMgtVCSigEntry 4 }
frMgtVCSigUserT391 OBJECT-TYPE
SYNTAX INTEGER (5..30)
UNITS "Seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the User-side
T391 link integrity verification polling timer
value for this UNI/NNI logical port. If the
logical port is not performing user-side
procedures, then this object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17]"
DEFVAL { 10 }
::= { frMgtVCSigEntry 5 }
frMgtVCSigNetN392 OBJECT-TYPE
SYNTAX INTEGER (1..10)
UNITS "Events"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the Network-
side N392 error threshold value (nN2 for LMI) for
this UNI/NNI logical port. If the logical port is
not performing network-side procedures, then this
object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17],
LMI [24]"
DEFVAL { 3 }
::= { frMgtVCSigEntry 6 }
frMgtVCSigNetN393 OBJECT-TYPE
SYNTAX INTEGER (1..10)
UNITS "Events"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the Network-
side N393 monitored events count value (nN3 for
LMI) for this UNI/NNI logical port. If the
logical port is not performing network-side
procedures, then this object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17],
LMI [24]"
DEFVAL { 4 }
::= { frMgtVCSigEntry 7 }
frMgtVCSigNetT392 OBJECT-TYPE
SYNTAX INTEGER (5..30)
UNITS "Seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the Network-
side T392 polling verification timer value (nT2
for LMI) for this UNI/NNI logical port. If the
logical port is not performing network-side
procedures, then this object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17],
LMI [24]"
DEFVAL { 15 }
::= { frMgtVCSigEntry 8 }
frMgtVCSigNetnN4 OBJECT-TYPE
SYNTAX INTEGER (5..5)
UNITS "Events"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the Network-
side nN4 maximum status enquires received value
for this UNI/NNI logical port. If the logical
port is not performing network-side procedures or
is not performing LMI procedures, then this object
is not instantiated.
This object applies only to LMI and always has a
value of 5."
REFERENCE "LMI [24]"
::= { frMgtVCSigEntry 9 }
frMgtVCSigNetnT3 OBJECT-TYPE
SYNTAX INTEGER (5 | 10 | 15 | 20 | 25 | 30)
UNITS "Seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the Network-
side nT3 timer (for nN4 status enquires received)
value for this UNI/NNI logical port. If the
logical port is not performing network-side
procedures or is not performing LMI procedures,
then this object is not instantiated.
This object applies only to LMI."
REFERENCE "LMI [24]"
DEFVAL { 20 }
::= { frMgtVCSigEntry 10 }
frMgtVCSigUserLinkRelErrors OBJECT-TYPE
SYNTAX Counter32
UNITS "Errors"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of user-side local in-channel
signaling link reliability errors (i.e., non-
receipt of Status/Status Enquiry messages or
invalid sequence numbers in a Link Integrity
Verification Information Element) for this UNI/NNI
logical port. If the logical port is not
performing user-side procedures, then this object
is not instantiated."
::= { frMgtVCSigEntry 11 }
frMgtVCSigUserProtErrors OBJECT-TYPE
SYNTAX Counter32
UNITS "Errors"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of user-side local in-channel
signaling protocol errors (i.e., protocol
discriminator, unnumbered information, message
type, call reference, and mandatory information
element errors) for this UNI/NNI logical port. If
the logical port is not performing user-side
procedures, then this object is not instantiated."
::= { frMgtVCSigEntry 12 }
frMgtVCSigUserChanInactive OBJECT-TYPE
SYNTAX Counter32
UNITS "Events"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the user-side channel was
declared inactive (i.e., N392 errors in N393
events) for this UNI/NNI logical port. If the
logical port is not performing user-side
procedures, then this object is not instantiated."
::= { frMgtVCSigEntry 13 }
frMgtVCSigNetLinkRelErrors OBJECT-TYPE
SYNTAX Counter32
UNITS "Errors"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of network-side local in-channel
signaling link reliability errors (i.e., non-
receipt of Status/Status Enquiry messages or
invalid sequence numbers in a Link Integrity
Verification Information Element) for this UNI/NNI
logical port."
::= { frMgtVCSigEntry 14 }
frMgtVCSigNetProtErrors OBJECT-TYPE
SYNTAX Counter32
UNITS "Errors"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of network-side local in-channel
signaling protocol errors (i.e., protocol
discriminator, message type, call reference, and
mandatory information element errors) for this
UNI/NNI logical port."
::= { frMgtVCSigEntry 15 }
frMgtVCSigNetChanInactive OBJECT-TYPE
SYNTAX Counter32
UNITS "Events"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the network-side channel was
declared inactive (i.e., N392 errors in N393
events) for this UNI/NNI logical port."
::= { frMgtVCSigEntry 16 }
frMgtVCSigProcedAdmin OBJECT-TYPE
SYNTAX INTEGER {
u2nnet(1),
bidirect(2),
u2nuser(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the local
in-channel signaling procedural role that is used
for this UNI/NNI logical port. Bidirectional
procedures implies that both user-side and
network-side procedural roles are used.
u2nnet(1) Logical port operates user to network
procedure in the role of the network
side
bidirect(2) Logical port operates the
bidirectional procedure (both user
and network side roles)
u2nuser(3) Logical port operates user to network
procedure in the role of the user
side"
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17]"
DEFVAL { u2nnet }
::= { frMgtVCSigEntry 17 }
frMgtVCSigUserN391Admin OBJECT-TYPE
SYNTAX INTEGER (1..255)
UNITS "Polls"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the desired
User-side N391 full status polling cycle value for
this UNI/NNI logical port. If the logical port is
not performing user-side (bidirectional)
procedures, then this object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17]"
::= { frMgtVCSigEntry 18 }
frMgtVCSigUserN392Admin OBJECT-TYPE
SYNTAX INTEGER (1..10)
UNITS "Events"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the desired
User-side N392 error threshold value for this
UNI/NNI logical port. If the logical port is not
performing user-side (bidirectional) procedures,
then this object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17]"
::= { frMgtVCSigEntry 19 }
frMgtVCSigUserN393Admin OBJECT-TYPE
SYNTAX INTEGER (1..10)
UNITS "Events"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the desired
User-side N393 monitored events count value for
this UNI/NNI logical port. If the logical port is
not performing user-side (bidirectional)
procedures, then this object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17]"
::= { frMgtVCSigEntry 20 }
frMgtVCSigUserT391Admin OBJECT-TYPE
SYNTAX INTEGER (5..30)
UNITS "Seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the desired
User-side T391 link integrity verification polling
timer value for this UNI/NNI logical port. If the
logical port is not performing user-side
procedures, then this object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17]"
::= { frMgtVCSigEntry 21 }
frMgtVCSigNetN392Admin OBJECT-TYPE
SYNTAX INTEGER (1..10)
UNITS "Events"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the desired
Network-side N392 error threshold value (nN2 for
LMI) for this UNI/NNI logical port. If the
logical port is not performing network-side
procedures, then this object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17],
LMI [24]"
::= { frMgtVCSigEntry 22 }
frMgtVCSigNetN393Admin OBJECT-TYPE
SYNTAX INTEGER (1..10)
UNITS "Events"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the desired
Network-side N393 monitored events count value
(nN3 for LMI) for this UNI/NNI logical port. If
the logical port is not performing network-side
procedures, then this object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17],
LMI [24]"
::= { frMgtVCSigEntry 23 }
frMgtVCSigNetT392Admin OBJECT-TYPE
SYNTAX INTEGER (5..30)
UNITS "Seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the desired
Network-side T392 polling verification timer value
(nT2 for LMI) for this UNI/NNI logical port. If
the logical port is not performing network-side
procedures, then this object is not instantiated."
REFERENCE "Q.933 Annex A [22],
T1.617 Annex D [17],
LMI [24]"
::= { frMgtVCSigEntry 24 }
frMgtVCSigNetnT3Admin OBJECT-TYPE
SYNTAX INTEGER (5 | 10 | 15 | 20 | 25 | 30)
UNITS "Seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object identifies the desired
Network-side nT3 timer (for nN4 status enquires
received) value for this UNI/NNI logical port. If
the logical port is not performing network-side
procedures or is not performing LMI procedures,
then this object is not instantiated. This object
applies only to LMI."
REFERENCE "LMI [24]"
::= { frMgtVCSigEntry 25 }
--
-- Frame Relay PVC End-points
--
frPVCEndptTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrPVCEndptEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Frame Relay PVC End-Point table. This table
is used to model a PVC end-point. This table
contains the traffic parameters and statistics for
a PVC end-point.
This table is used to identify the traffic
parameters for a bi-directional PVC segment end-
point, and it also provides statistics for a PVC
segment end-point.
A PVC segment end-point is identified by a UNI/NNI
logical port index value and DLCI index value.
If the frame relay service provider allows the
frame relay CNM subscriber to create, modify or
delete PVCs using SNMP, then this table is used to
identify and reserve the requested traffic
parameters of each PVC segment end-point. The
Connection table is used to 'connect' the end-
points together. Not all implementations will
support the capability of
creating/modifying/deleting PVCs using SNMP as a
feature of frame relay CNM service.
Uni-directional PVCs are modeled with zero valued
traffic parameters in one of the directions (In or
Out direction) in this table.
To create a PVC, the following procedures shall be
followed:
1) Create the entries for the PVC segment
endpoints in the frPVCEndptTable by specifying
the traffic parameters for the bi-directional
PVC segment endpoints. As shown in figure 2, a
point-to-point PVC has two endpoints, thus two
entries in this table. Uni-directional PVCs
are modeled with zero valued traffic
parameters in one direction; all the `In'
direction parameters for one frame relay PVC
End-point or all the `Out' direction
parameters for the other frame relay PVC
Endpoint.
In _____________________________ Out
>>>>>>| |>>>>>>>>
______| Frame Relay Network |________
Out | | In
<<<<<<|_____________________________|<<<<<<<<
Frame Relay Frame Relay
PVC PVC
Endpoint Endpoint
Figure 2, PVC Terminology
2) Go to the Frame Relay Connection Group."
::= { frnetservObjects 3 }
frPVCEndptEntry OBJECT-TYPE
SYNTAX FrPVCEndptEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Frame Relay PVC Endpoint table."
INDEX { ifIndex, frPVCEndptDLCIIndex }
::= { frPVCEndptTable 1 }
FrPVCEndptEntry ::=
SEQUENCE {
frPVCEndptDLCIIndex Integer32,
frPVCEndptInMaxFrameSize Integer32,
frPVCEndptInBc Integer32,
frPVCEndptInBe Integer32,
frPVCEndptInCIR Integer32,
frPVCEndptOutMaxFrameSize Integer32,
frPVCEndptOutBc Integer32,
frPVCEndptOutBe Integer32,
frPVCEndptOutCIR Integer32,
frPVCEndptConnectIdentifier Integer32,
frPVCEndptRowStatus RowStatus,
frPVCEndptRcvdSigStatus INTEGER,
frPVCEndptInFrames Counter32,
frPVCEndptOutFrames Counter32,
frPVCEndptInDEFrames Counter32,
frPVCEndptInExcessFrames Counter32,
frPVCEndptOutExcessFrames Counter32,
frPVCEndptInDiscards Counter32,
frPVCEndptInOctets Counter32,
frPVCEndptOutOctets Counter32,
frPVCEndptInDiscardsDESet Counter32,
frPVCEndptInFramesFECNSet Counter32,
frPVCEndptOutFramesFECNSet Counter32,
frPVCEndptInFramesBECNSet Counter32,
frPVCEndptOutFramesBECNSet Counter32,
frPVCEndptInCongDiscards Counter32,
frPVCEndptInDECongDiscards Counter32,
frPVCEndptOutCongDiscards Counter32,
frPVCEndptOutDECongDiscards Counter32,
frPVCEndptOutDEFrames Counter32,
frPVCEndptAtmIwfConnIndex Integer32
}
frPVCEndptDLCIIndex OBJECT-TYPE
SYNTAX Integer32 (16..4194303)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is equal to the DLCI
value for this PVC end-point.
The values are restricted to the legal range for
the size of address field supported by the logical
port (frLportAddrDLCILen)."
REFERENCE "Q.922 [25]"
::= { frPVCEndptEntry 1 }
frPVCEndptInMaxFrameSize OBJECT-TYPE
SYNTAX Integer32 (1..4096)
UNITS "Octets"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object is the size in octets of
the largest frame relay information field for this
PVC end-point in the ingress direction (into the
frame relay network). The value of
frPVCEndptInMaxFrameSize must be less than or
equal to the corresponding ifMtu for this frame
relay UNI/NNI logical port."
REFERENCE "FRF.1 [31]
Q.922 [25]
Q.933 [22]"
DEFVAL { 1600 }
::= { frPVCEndptEntry 2 }
frPVCEndptInBc OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
UNITS "Bits"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object is equal to the
committed burst size (Bc) parameter (measured in
bits) for this PVC end-point in the ingress
direction (into the frame relay network).
Note that the max value of this range is lower
than the max value allowed by Q.933 (16383 *
10**6).
Note that the value is encoded in bits whilst the
Q.933 Link layer core parameters information
element encodes this information using octet
units."
REFERENCE "Q.933 [22]"
::= { frPVCEndptEntry 3 }
frPVCEndptInBe OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
UNITS "Bits"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object is equal to the excess
burst size (Be) parameter (measured in bits) for
this PVC end-point in the ingress direction (into
the frame relay network).
Note that the max value of this range is lower
than the max value allowed by Q.933 (16383 *
10**6).
Note that the value is encoded in bits whilst the
Q.933 Link layer core parameters information
element encodes this information using octet
units."
REFERENCE "Q.933 [22]"
::= { frPVCEndptEntry 4 }
frPVCEndptInCIR OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
UNITS "Bits per Second"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object is equal to the
committed information rate (CIR) parameter
(measured in bits per second) for this PVC end-
point in the ingress direction (into the frame
relay network).
Note that the max value of this range is lower
than the max value allowed by Q.933 (2047 *
10**6)."
REFERENCE "Q.933 [22]"
::= { frPVCEndptEntry 5 }
frPVCEndptOutMaxFrameSize OBJECT-TYPE
SYNTAX Integer32 (1..4096)
UNITS "Octets"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object is the size in octets of
the largest frame relay information field for this
PVC end-point in the egress direction (out of the
frame relay network). The value of
frPVCEndptOutMaxFrameSize must be less than or
equal to the corresponding ifMtu for this frame
relay UNI/NNI logical port."
REFERENCE "FRF.1 [31]
Q.922 [25]
Q.933 [22]"
DEFVAL { 1600 }
::= { frPVCEndptEntry 6 }
frPVCEndptOutBc OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
UNITS "Bits"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object is equal to the
committed burst size (Bc) parameter (measured in
bits) for this PVC end-point in the egress
direction (out of the frame relay network).
Note that the max value of this range is lower
than the max value allowed by Q.933 (16383 *
10**6).
Note that the value is encoded in bits whilst the
Q.933 Link layer core parameters information
element encodes this information using octet
units."
REFERENCE "Q.933 [22]"
::= { frPVCEndptEntry 7 }
frPVCEndptOutBe OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
UNITS "Bits"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object is equal to the excess
burst size (Be) parameter (measured in bits) for
this PVC end-point in the egress direction (out of
the frame relay network).
Note that the max value of this range is lower
than the max value allowed by Q.933 (16383 *
10**6).
Note that the value is encoded in bits whilst the
Q.933 Link layer core parameters information
element encodes this information using octet
units."
REFERENCE "Q.933 [22]"
::= { frPVCEndptEntry 8 }
frPVCEndptOutCIR OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
UNITS "Bits per Second"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object is equal to the
committed information rate (CIR) parameter
(measured in bits per second) for this PVC end-
point in the egress direction (out of the frame
relay network).
Note that the max value of this range is lower
than the max value allowed by Q.933 (2047 *
10**6)."
REFERENCE "Q.933 [22]"
::= { frPVCEndptEntry 9 }
frPVCEndptConnectIdentifier OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to associate PVC end-points
as being part of one PVC segment connection. This
value of this object is equal to the value of
frPVCConnectIndex, which is used as one of the
indices into the frPVCConnectTable.
A connection that has been cross-connected via the
FR/ATM PVC Service IWF cross-connect table will
return the value zero when this object is read. In
case of these interworked connections, the
frPVCEndptAtmIwfConnIndex object must be accessed
to select the entry in the FR/ATM PVC Service IWF
cross-connect table.
The value of this object is provided by the agent,
after the associated entries in the
frPVCConnectTable or frAtmIwfConnectionTable have
been created."
::= { frPVCEndptEntry 10 }
frPVCEndptRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create new rows in this
table, modify existing rows, and to delete
existing rows. To create a new PVC, the entries
for the PVC segment end-points in the
frPVCEndptTable must first be created. Next, the
frPVCConnectTable is used to associate the frame
relay PVC segment end-points. In order for the
manager to have the necessary error diagnostics,
the frPVCEndptRowStatus object must initially be
set to `createAndWait(5)'. While the
frPVCEndptRowStatus object is in the
`createAndWait(5)' state, the manager can set each
columnar object and get the necessary error
diagnostics. The frPVCEndptRowStatus object may
not be set to `active(1)' unless the following
columnar objects exist in this row:
frPVCEndptInMaxFrameSize, frPVCEndptInBc,
frPVCEndptInBe, frPVCEndptInCIR,
frPVCEndptOutMaxFrameSize, frPVCEndptOutBc,
frPVCEndptOutBe, and frPVCEndptOutCIR."
::= { frPVCEndptEntry 11 }
frPVCEndptRcvdSigStatus OBJECT-TYPE
SYNTAX INTEGER {
deleted(1),
active(2),
inactive(3),
none(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the PVC
status received via the local in-channel signaling
procedures for this PVC end-point. This object is
only pertinent for interfaces that perform the
bidirectional procedures.
Each value has the following meaning:
deleted(1): This PVC is not listed in the full
status reports received from the
user device. The object retains
this value for as long as the PVC
is not listed in the full status
reports
active(2): This PVC is reported as active, or
operational, by the user device.
inactive(3): This PVC is reported as inactive,
or non-operational, by the user
device.
none(4): This interface is only using the
network-side in-channel signaling
procedures, so this object does
not apply."
::= { frPVCEndptEntry 12 }
frPVCEndptInFrames OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames received by the network
(ingress) for this PVC end-point. This includes
any frames discarded by the network due to
submitting more than Bc + Be data or due to any
network congestion recovery procedures."
::= { frPVCEndptEntry 13 }
frPVCEndptOutFrames OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames sent by the network (egress)
regardless of whether they are Bc or Be frames for
this PVC end-point."
::= { frPVCEndptEntry 14 }
frPVCEndptInDEFrames OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames received by the network
(ingress) with the DE bit set to (1) for this PVC
end-point."
::= { frPVCEndptEntry 15 }
frPVCEndptInExcessFrames OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames received by the network
(ingress) for this PVC end-point which were
treated as excess traffic. Frames which are sent
to the network with DE set to zero are treated as
excess when more than Bc bits are submitted to the
network during the Committed Information Rate
Measurement Interval (Tc). Excess traffic may or
may not be discarded at the ingress if more than
Bc + Be bits are submitted to the network during
Tc. Traffic discarded at the ingress is not
recorded in frPVCEndptInExcessFrames. Frames
which are sent to the network with DE set to one
are also treated as excess traffic."
::= { frPVCEndptEntry 16 }
frPVCEndptOutExcessFrames OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames sent by the network (egress)
for this PVC end-point which were treated as
excess traffic. (The DE bit may be set to one.)"
::= { frPVCEndptEntry 17 }
frPVCEndptInDiscards OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames received by the network
(ingress) that were discarded due to traffic
enforcement for this PVC end-point. Congestion
discards are not counted in this object."
::= { frPVCEndptEntry 18 }
frPVCEndptInOctets OBJECT-TYPE
SYNTAX Counter32
UNITS "Octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets received by the network
(ingress) for this PVC end-point. This counter
should only count octets from the beginning of the
frame relay header field to the end of user data.
If the network supporting frame relay can not
count octets, then this count should be an
approximation."
::= { frPVCEndptEntry 19 }
frPVCEndptOutOctets OBJECT-TYPE
SYNTAX Counter32
UNITS "Octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets sent by the network (egress)
for this PVC end-point. This counter should only
count octets from the beginning of the frame relay
header field to the end of user data. If the
network supporting frame relay can not count
octets, then this count should be an
approximation."
::= { frPVCEndptEntry 20 }
frPVCEndptInDiscardsDESet OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames received by the network
(ingress) that were discarded with the DE bit set
due to traffic enforcement for this PVC end-point.
Congestion discards are not counted in this
object."
::= { frPVCEndptEntry 21 }
frPVCEndptInFramesFECNSet OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames received by the network
(ingress) that have the FECN bit set for this PVC
end-point."
::= { frPVCEndptEntry 22 }
frPVCEndptOutFramesFECNSet OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames sent by the network (egress)
that have the FECN bit set for this PVC end-
point."
::= { frPVCEndptEntry 23 }
frPVCEndptInFramesBECNSet OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames received by the network
(ingress) that have the BECN bit set for this PVC
end-point."
::= { frPVCEndptEntry 24 }
frPVCEndptOutFramesBECNSet OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames sent by the network (egress)
that have the BECN bit set for this PVC end-
point."
::= { frPVCEndptEntry 25 }
frPVCEndptInCongDiscards OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames received by the network
(ingress) that were discarded due to input buffer
congestion, rather than traffic enforcement, for
this PVC end-point."
::= { frPVCEndptEntry 26 }
frPVCEndptInDECongDiscards OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames counted by
frPVCEndptInCongDiscards with the DE bit set to
(1)."
::= { frPVCEndptEntry 27 }
frPVCEndptOutCongDiscards OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames sent by the network (egress)
that were discarded due to output buffer
congestion for this PVC end-point."
::= { frPVCEndptEntry 28 }
frPVCEndptOutDECongDiscards OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames counted by
frPVCEndptOutCongDiscards with the DE bit set to
(1)."
::= { frPVCEndptEntry 29 }
frPVCEndptOutDEFrames OBJECT-TYPE
SYNTAX Counter32
UNITS "Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames sent by the network (egress)
with the DE bit set to (1) for this PVC end-
point."
::= { frPVCEndptEntry 30 }
frPVCEndptAtmIwfConnIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the index value of the
FR/ATM cross-connect table entry used to link the
frame relay PVC with an ATM PVC.
Each row of the frPVCEndptTable that is not
cross-connected with an ATM PVC must return the
value zero when this object is read.
The value of this object is initialized by the
agent after the associated entries in the
frAtmIwfConnectionTable have been created.
The value of this object is reset to zero
following destruction of the associated entry in
the frAtmIwfConnectionTable"
::= { frPVCEndptEntry 31 }
--
-- Frame Relay PVC Connections
--
frPVCConnectIndexValue OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object returns a hint to be used for
frPVCConnectIndex when creating entries in the
frPVCConnectTable.
The value 0 indicates that no unassigned entries
are available.
To obtain the frPVCConnectIndex value for a new
entry, the manager issues a management protocol
retrieval operation to obtain the current value of
this object. After each retrieval, the agent must
modify the value to the next unassigned index to
prevent assignment of the same value to multiple
management systems.
A management system should repeat the read to
obtain a new value should an attempt to create the
new row using the previously returned hint fail."
::= { frnetservObjects 4 }
frPVCConnectTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrPVCConnectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Frame Relay PVC Connect Table is used to
model the bi-directional PVC segment flows
including: point-to-point PVCs, point-to-
multipoint PVCs, and multipoint-to-multipoint
PVCs.
This table has read-create access and is used to
associate PVC end-points together as belonging to
one connection. The frPVCConnectIndex is used to
associate all the bi-directional flows. Not all
implementations will support the capability of
creating/modifying/deleting PVCs using SNMP as a
feature of frame relay CNM service.
Once the entries in the frPVCEndptTable are
created, the following step are used to associate
the PVC end-points as belonging to one PVC
connection:
1) Obtain a unique frPVCConnectIndex
using the frPVCConnectIndexValue object.
2) Connect the PVC segment endpoints together
with the applicable frPVCConnectIndex value
obtained via frPVCConnectIndexValue. The
entries in this table are created by using
the frPVCConnectRowStatus object.
3) The agent will provide the value of the
corresponding instances of
frPVCEndptConnectIdentifier with the
frPVCConnectIndex value.
4) Set frPVCConnectAdminStatus to `active(1)' in
all rows for this PVC segment to turn the
PVC on.
For example, the Frame Relay PVC Connection Group
models a bi-directional, point-to-point PVC
segment as one entry in this table.
Frame Relay Frame Relay
Network Network
Low Port High Port
__________________________________
| |
_____| >> from low to high PVC flow >> |_____
| << from high to low PVC flow << |
|__________________________________|
The terms low and high are chosen to represent
numerical ordering of a PVC segment's endpoints
for representation in this table. That is, the
endpoint with the lower value of ifIndex is termed
'low', while the opposite endpoint of the segment
is termed 'high'. This terminology is to provide
directional information; for example the
frPVCConnectL2hOperStatus and
frPVCConnectH2lOperStatus as illustrated above.
If the Frame Relay Connection table is used to
model a unidirectional PVC, then one direction
(either from low to high or from high to low) has
its Operational Status equal to down.
A PVC segment is a portion of a PVC that traverses
one Frame Relay Network, and a PVC segment is
identified by its two end-points (UNI/NNI logical
port index value and DLCI index value) through one
Frame Relay Network."
::= { frnetservObjects 5 }
frPVCConnectEntry OBJECT-TYPE
SYNTAX FrPVCConnectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Frame Relay PVC Connect table.
This entry is used to model a PVC segment in two
directions."
INDEX { frPVCConnectIndex,
frPVCConnectLowIfIndex,
frPVCConnectLowDLCIIndex,
frPVCConnectHighIfIndex,
frPVCConnectHighDLCIIndex }
::= { frPVCConnectTable 1 }
FrPVCConnectEntry ::=
SEQUENCE {
frPVCConnectIndex Integer32,
frPVCConnectLowIfIndex InterfaceIndex,
frPVCConnectLowDLCIIndex Integer32,
frPVCConnectHighIfIndex InterfaceIndex,
frPVCConnectHighDLCIIndex Integer32,
frPVCConnectAdminStatus INTEGER,
frPVCConnectL2hOperStatus INTEGER,
frPVCConnectH2lOperStatus INTEGER,
frPVCConnectL2hLastChange TimeStamp,
frPVCConnectH2lLastChange TimeStamp,
frPVCConnectRowStatus RowStatus,
frPVCConnectUserName SnmpAdminString,
frPVCConnectProviderName SnmpAdminString
}
frPVCConnectIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is equal to the
frPVCConnectIndexValue obtained to uniquely
identify this PVC segment connection."
::= { frPVCConnectEntry 1 }
frPVCConnectLowIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is equal to IF-MIB
ifIndex value of the UNI/NNI logical port for this
PVC segment. The term low implies that this PVC
segment end-point has the numerically lower
ifIndex value than the connected/associated PVC
segment end-point.
RFC 1604 permitted a zero value for this object to
identify termination at a non-frame relay
interface. However, this cross-connect table is
limited to frame relay connections. See the frame
relay/ATM IWF MIB [28] for the cross-connect table
used for those types of connections."
::= { frPVCConnectEntry 2 }
frPVCConnectLowDLCIIndex OBJECT-TYPE
SYNTAX Integer32 (16..4194303)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is equal to the DLCI
value for this end-point of the PVC segment."
REFERENCE "Q.922 [25]"
::= { frPVCConnectEntry 3 }
frPVCConnectHighIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is equal to IF-MIB
ifIndex value for the UNI/NNI logical port for
this PVC segment. The term high implies that this
PVC segment end-point has the numerically higher
ifIndex value than the connected/associated PVC
segment end-point."
::= { frPVCConnectEntry 4 }
frPVCConnectHighDLCIIndex OBJECT-TYPE
SYNTAX Integer32 (16..4194303)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is equal to the egress
DLCI value for this end-point of the PVC segment."
REFERENCE "Q.922 [25]"
::= { frPVCConnectEntry 5 }
frPVCConnectAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
active(1),
inactive(2),
testing(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object identifies the desired
administrative status of this bi-directional PVC
segment. The active(1) state means the PVC
segment is currently operational; the inactive(2)
state means the PVC segment is currently not
operational; the testing(3) state means the PVC
segment is currently undergoing a test. This
state is set by an administrative entity. This
value affects the PVC status indicated across the
ingress NNI/UNI of both end-points of the bi-
directional PVC segment. When a PVC segment
connection is created using this table, this
object is initially set to `inactive(2)'. After
the frPVCConnectRowStatus object is set to
`active(1)' (and the corresponding/associated
entries in the frPVCEndptTable have their
frPVCEndptRowStatus object set to `active(1)'),
the frPVCConnectAdminStatus object may be set to
`active(1)' to turn on the PVC segment
connection."
::= { frPVCConnectEntry 6 }
frPVCConnectL2hOperStatus OBJECT-TYPE
SYNTAX INTEGER {
active(1),
inactive(2),
testing(3),
unknown(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the current
operational status of the PVC segment connection
in one direction; (i.e., in the low to high
direction). This value affects the PVC status
indicated across the ingress NNI/UNI (low side) of
the PVC segment.
The values mean:
active(1) - PVC is currently operational
inactive(2) - PVC is currently not operational.
This may be because of an underlying
LMI or DS1 failure.
testing(3) - PVC is currently undergoing a test.
This may be because of an underlying
frLport or DS1 undergoing a test.
unknown(4) - the status of the PVC currently can
not be determined."
::= { frPVCConnectEntry 7 }
frPVCConnectH2lOperStatus OBJECT-TYPE
SYNTAX INTEGER {
active(1),
inactive(2),
testing(3),
unknown(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object identifies the current
operational status of the PVC segment connection
in one direction; (i.e., in the high to low
direction).. This value affects the PVC status
indicated across the ingress NNI/UNI (high side)
of the PVC segment.
The values mean:
active(1) - PVC is currently operational
inactive(2) - PVC is currently not operational.
This may be because of an underlying
LMI or DS1 failure.
testing(3) - PVC is currently undergoing a test.
This may be because of an underlying
frLport or DS1 undergoing a test.
unknown(4) - the status of the PVC currently can
not be determined."
::= { frPVCConnectEntry 8 }
frPVCConnectL2hLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the Interface MIB's sysUpTime object
at the time this PVC segment entered its current
operational state in the low to high direction.
If the current state was entered prior to the last
re-initialization of the FRS agent, then this
object contains a zero value."
::= { frPVCConnectEntry 9 }
frPVCConnectH2lLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the Interface MIB's sysUpTime object
at the time this PVC segment entered its current
operational state in the high to low direction.
If the current state was entered prior to the last
re-initialization of the FRS agent, then this
object contains a zero value."
::= { frPVCConnectEntry 10 }
frPVCConnectRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this entry in the
frPVCConnectTable. This variable is used to
create new connections for the PVC end-points and
to change existing connections of the PVC end-
points. This object must be initially set to
`createAndWait(5)'. In this state, the agent
checks the parameters in the associated entries in
the frPVCEndptTable to verify that the PVC end-
points can be connected (i.e., the In parameters
for one PVC end-point are equal to the Out
parameters for the other PVC end-point). This
object can not be set to `active(1)' unless the
following columnar object exists in this row:
frPVCConnectAdminStatus. The agent also supplies
the associated value of frPVCConnectIndex for the
frPVCEndptConnectIdentifier instances. To turn on
a PVC segment connection, the
frPVCConnectAdminStatus is set to `active(1)'."
::= { frPVCConnectEntry 11 }
frPVCConnectUserName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is a service user assigned textual
representation of a PVC."
::= { frPVCConnectEntry 12 }
frPVCConnectProviderName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is a system supplied textual representation
of PVC. It is assigned by the service provider."
::= { frPVCConnectEntry 13 }
--
-- The Frame Relay Accounting
--
frAccountPVCTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrAccountPVCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Frame Relay Accounting PVC table. This table
is used to perform accounting on a PVC segment
end-point basis."
::= { frnetservObjects 6 }
frAccountPVCEntry OBJECT-TYPE
SYNTAX FrAccountPVCEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Frame Relay Accounting PVC
table."
INDEX { ifIndex,
frAccountPVCDLCIIndex }
::= { frAccountPVCTable 1 }
FrAccountPVCEntry ::=
SEQUENCE {
frAccountPVCDLCIIndex Integer32,
frAccountPVCSegmentSize Integer32,
frAccountPVCInSegments Counter32,
frAccountPVCOutSegments Counter32
}
frAccountPVCDLCIIndex OBJECT-TYPE
SYNTAX Integer32 (16..4194303)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is equal to the DLCI
value for this PVC segment end-point."
REFERENCE "Q.922 [25]"
::= { frAccountPVCEntry 1 }
frAccountPVCSegmentSize OBJECT-TYPE
SYNTAX Integer32
UNITS "Octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object is equal to the Segment
Size for this PVC segment end-point."
::= { frAccountPVCEntry 2 }
frAccountPVCInSegments OBJECT-TYPE
SYNTAX Counter32
UNITS "Segments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object is equal to the number
of segments received by this PVC segment end-
point."
::= { frAccountPVCEntry 3 }
frAccountPVCOutSegments OBJECT-TYPE
SYNTAX Counter32
UNITS "Segments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object is equal to the number
of segments sent by this PVC segment end-point."
::= { frAccountPVCEntry 4 }
--
-- Accounting on a Frame Relay Logical Port
--
frAccountLportTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrAccountLportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Frame Relay Accounting Logical Port table.
This table is used to perform accounting on a
UNI/NNI Logical Port basis."
::= { frnetservObjects 7 }
frAccountLportEntry OBJECT-TYPE
SYNTAX FrAccountLportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Frame Relay Accounting Logical
Port table."
INDEX { ifIndex }
::= { frAccountLportTable 1 }
FrAccountLportEntry ::=
SEQUENCE {
frAccountLportSegmentSize
Integer32,
frAccountLportInSegments
Counter32,
frAccountLportOutSegments
Counter32
}
frAccountLportSegmentSize OBJECT-TYPE
SYNTAX Integer32
UNITS "Octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object is equal to the Segment
Size for this UNI/NNI logical port."
::= { frAccountLportEntry 1 }
frAccountLportInSegments OBJECT-TYPE
SYNTAX Counter32
UNITS "Segments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object is equal to the number
of segments received by this UNI/NNI logical
port."
::= { frAccountLportEntry 2 }
frAccountLportOutSegments OBJECT-TYPE
SYNTAX Counter32
UNITS "Segments"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of this object is equal to the number
of segments sent by this UNI/NNI logical port."
::= { frAccountLportEntry 3 }
--
-- Frame Relay Network Service Notifications
--
frPVCConnectStatusChange NOTIFICATION-TYPE
OBJECTS { frPVCConnectIndex,
frPVCConnectLowIfIndex,
frPVCConnectLowDLCIIndex,
frPVCConnectHighIfIndex,
frPVCConnectHighDLCIIndex,
frPVCConnectL2hOperStatus,
frPVCConnectH2lOperStatus,
frPVCEndptRcvdSigStatus }
STATUS deprecated
DESCRIPTION
"Refer to the description of the
frPVCConnectStatusNotif notification that has
replaced this notification. The notification is
deprecated due to the incorrect inclusion of index
values and to take advantage of the trap prefix
for automatic conversion from SMIv2 to SMIv1 by
making the one but last sub-ID a zero (i.e. the
so-called trap prefix)."
::= { frnetservTraps 1 }
frPVCConnectStatusNotif NOTIFICATION-TYPE
OBJECTS { frPVCConnectL2hOperStatus,
frPVCConnectH2lOperStatus,
frPVCEndptRcvdSigStatus }
STATUS current
DESCRIPTION
"This notification indicates that the indicated
PVC has changed state.
This notification is not sent if an FR-UNI changes
state; a linkDown or linkUp notification should be
sent instead. The first instance of
frPVCEndptRcvdSigStatus is for the endpoint with
LowIfIndex, LowDLCIIndex. The second instance of
frPVCEndptRcvdSigStatus is for the endpoint with
HighIfIndex, HighDLCIIndex"
::= { frnetservTrapsPrefix 2 }
-- Conformance Information
frnetservConformance OBJECT IDENTIFIER
::= { frnetservMIB 3 }
frnetservGroups OBJECT IDENTIFIER
::= { frnetservConformance 1 }
frnetservCompliances OBJECT IDENTIFIER
::= { frnetservConformance 2 }
--
-- Service (Read-only) Modules
--
frnetservCompliance2 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMP entities which
have Frame Relay Network Service Interfaces.
The distinction between 'service' and 'switch' is
that a 'switch' is configured via this MIB.
Hence, the various read/write objects have write
capability. A 'service' represents a passive
monitor-only customer network management
interface. The various read/write objects are
restricted to read-only capability."
MODULE -- this module
MANDATORY-GROUPS { frnetservLportGroup2,
frnetservMgtVCSigGroup,
frnetservPVCEndptGroup,
frnetservPVCEndptGroup2,
frnetservPVCConnectGroup,
frnetservPVCConnectNamesGroup,
frnetservPVCNotifGroup2 }
GROUP frnetservAccountPVCGroup
DESCRIPTION
"This group is optional for frame relay
interfaces. It is mandatory if and only if
accounting is performed on a PVC basis this frame
relay interface."
GROUP frnetservAccountLportGroup
DESCRIPTION
"This group is optional for frame relay
interfaces. It is mandatory if and only if
accounting is performed on a logical port basis
this frame relay interface."
OBJECT frPVCEndptInMaxFrameSize
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptInBc
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptInBe
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptInCIR
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptOutMaxFrameSize
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptOutBc
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptOutBe
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptOutCIR
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptRowStatus
-- subset of RowStatus
SYNTAX INTEGER { active(1) }
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, and only one of the
six enumerated values for the RowStatus textual
convention need be supported, specifically:
active(1)."
OBJECT frPVCConnectAdminStatus
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCConnectRowStatus
-- subset of RowStatus
SYNTAX INTEGER { active(1) }
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, and only one of the
six enumerated values for the RowStatus textual
convention need be supported, specifically:
active(1)."
OBJECT frLportFragControl
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frLportFragSize
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCConnectUserName
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCConnectProviderName
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { frnetservCompliances 2 }
--
-- Switch (Configuration) Compliance
--
frnetSwitchCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMP entities which
have Frame Relay Network Switch objects.
The distinction between 'service' and 'switch' is
that a 'switch' is configured via this MIB.
Hence, the various read/write objects have write
capability. A 'service' represents a passive
monitor-only customer network management
interface. The various read/write objects are
restricted to read-only capability."
MODULE -- this module
MANDATORY-GROUPS { frnetservLportGroup2,
frnetservLportAdminGroup,
frnetservMgtVCSigGroup,
frnetservMgtVCSigAdminGroup,
frnetservPVCEndptGroup,
frnetservPVCEndptGroup2,
frnetservPVCConnectGroup,
frnetservPVCConnectNamesGroup,
frnetservPVCNotifGroup2 }
GROUP frnetservAccountPVCGroup
DESCRIPTION
"This group is optional for frame relay
interfaces. It is mandatory if and only if
accounting is performed on a PVC basis this frame
relay interface."
GROUP frnetservAccountLportGroup
DESCRIPTION
"This group is optional for frame relay
interfaces. It is mandatory if and only if
accounting is performed on a logical port basis
this frame relay interface."
::= { frnetservCompliances 3 }
--
-- Historical RFC 1604 Compliance Modules
--
frnetservCompliance MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for SNMP entities which
have Frame Relay Network Service Interfaces.
This compliance statement has been deprecated in
favor of frnetservCompliance2. The new compliance
module expands the mandatory groups to include
notification and other new objects."
MODULE -- this module
MANDATORY-GROUPS { frnetservLportGroup,
frnetservMgtVCSigGroup,
frnetservPVCEndptGroup,
frnetservPVCConnectGroup }
GROUP frnetservAccountPVCGroup
DESCRIPTION
"This group is optional for Frame Relay
interfaces. It is mandatory if and only if
accounting is performed on a PVC basis this Frame
Relay interface."
GROUP frnetservAccountLportGroup
DESCRIPTION
"This group is optional for Frame Relay
interfaces. It is mandatory if and only if
accounting is performed on a logical port basis
this Frame Relay interface."
OBJECT frPVCEndptInMaxFrameSize
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptInBc
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptInBe
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptInCIR
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptOutMaxFrameSize
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptOutBc
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptOutBe
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptOutCIR
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCEndptRowStatus
-- subset of RowStatus
SYNTAX INTEGER { active(1) }
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, and only one of the
six enumerated values for the RowStatus textual
convention need be supported, specifically:
active(1)."
OBJECT frPVCConnectAdminStatus
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT frPVCConnectRowStatus
-- subset of RowStatus
SYNTAX INTEGER { active(1) }
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, and only one of the
six enumerated values for the RowStatus textual
convention need be supported, specifically:
active(1)."
::= { frnetservCompliances 1 }
--
-- Frame Relay Service MIB Object Groups
--
frnetservLportGroup OBJECT-GROUP
OBJECTS { frLportNumPlan, frLportContact, frLportLocation,
frLportType,
frLportAddrDLCILen, frLportVCSigProtocol,
frLportVCSigPointer }
STATUS deprecated
DESCRIPTION
"A collection of objects providing information
applicable to a Frame Relay Logical Port. This
group has been deprecated to eliminate reference
to the object frLportVCSigPointer.
Use the new group frnetservLportGroup2 as a
replacement for this group."
::= { frnetservGroups 1 }
frnetservMgtVCSigGroup OBJECT-GROUP
OBJECTS { frMgtVCSigProced,
frMgtVCSigUserN391,
frMgtVCSigUserN392,
frMgtVCSigUserN393,
frMgtVCSigUserT391,
frMgtVCSigNetN392,
frMgtVCSigNetN393,
frMgtVCSigNetT392,
frMgtVCSigNetnN4,
frMgtVCSigNetnT3,
frMgtVCSigUserLinkRelErrors,
frMgtVCSigUserProtErrors,
frMgtVCSigUserChanInactive,
frMgtVCSigNetLinkRelErrors,
frMgtVCSigNetProtErrors,
frMgtVCSigNetChanInactive }
STATUS current
DESCRIPTION
"A collection of objects providing information
applicable to the Local In-Channel Signaling
Procedures used for a UNI/NNI logical port."
::= { frnetservGroups 2 }
frnetservPVCEndptGroup OBJECT-GROUP
OBJECTS { frPVCConnectIndexValue,
frPVCEndptInMaxFrameSize,
frPVCEndptInBc,
frPVCEndptInBe,
frPVCEndptInCIR,
frPVCEndptOutMaxFrameSize,
frPVCEndptOutBc,
frPVCEndptOutBe,
frPVCEndptOutCIR,
frPVCEndptConnectIdentifier,
frPVCEndptRowStatus,
frPVCEndptRcvdSigStatus,
frPVCEndptInFrames,
frPVCEndptOutFrames,
frPVCEndptInDEFrames,
frPVCEndptInExcessFrames,
frPVCEndptOutExcessFrames,
frPVCEndptInDiscards,
frPVCEndptInOctets,
frPVCEndptOutOctets }
STATUS current
DESCRIPTION
"A collection of objects providing information
applicable to a Frame Relay PVC end-point."
::= { frnetservGroups 3 }
frnetservPVCConnectGroup OBJECT-GROUP
OBJECTS { frPVCConnectAdminStatus,
frPVCConnectL2hOperStatus,
frPVCConnectH2lOperStatus,
frPVCConnectL2hLastChange,
frPVCConnectH2lLastChange,
frPVCConnectRowStatus }
STATUS current
DESCRIPTION
"A collection of objects providing information
applicable to a Frame Relay PVC connection."
::= { frnetservGroups 4 }
frnetservAccountPVCGroup OBJECT-GROUP
OBJECTS { frAccountPVCSegmentSize,
frAccountPVCInSegments,
frAccountPVCOutSegments }
STATUS current
DESCRIPTION
"A collection of objects providing accounting
information application to a Frame Relay PVC end-
point."
::= { frnetservGroups 5 }
frnetservAccountLportGroup OBJECT-GROUP
OBJECTS { frAccountLportSegmentSize,
frAccountLportInSegments,
frAccountLportOutSegments }
STATUS current
DESCRIPTION
"A collection of objects providing accounting
information application to a Frame Relay logical
port."
::= { frnetservGroups 6 }
frnetservLportGroup2 OBJECT-GROUP
OBJECTS { frLportNumPlan,
frLportContact,
frLportLocation,
frLportType,
frLportAddrDLCILen,
frLportVCSigProtocol,
frLportFragControl,
frLportFragSize }
STATUS current
DESCRIPTION
"A collection of objects providing information
applicable to a Frame Relay Logical Port.
This new version of the Logical Port Group
eliminates the frLportVCSigPointer and adds
support for fragmentation."
::= { frnetservGroups 7 }
frnetservPVCEndptGroup2 OBJECT-GROUP
OBJECTS { frPVCEndptInDiscardsDESet,
frPVCEndptInFramesFECNSet,
frPVCEndptOutFramesFECNSet,
frPVCEndptInFramesBECNSet,
frPVCEndptOutFramesBECNSet,
frPVCEndptInCongDiscards,
frPVCEndptInDECongDiscards,
frPVCEndptOutCongDiscards,
frPVCEndptOutDECongDiscards,
frPVCEndptOutDEFrames,
frPVCEndptAtmIwfConnIndex }
STATUS current
DESCRIPTION
"Additions to the PVC end-point group. These
additions provide new frame counters to track
frame loss. In addition, the new FR/ATM IWF MIB
cross-connect index is included."
::= { frnetservGroups 8 }
frnetservPVCConnectNamesGroup OBJECT-GROUP
OBJECTS { frPVCConnectUserName,
frPVCConnectProviderName }
STATUS current
DESCRIPTION
"Additions to the PVC Connect Group."
::= { frnetservGroups 9 }
frnetservLportAdminGroup OBJECT-GROUP
OBJECTS { frLportDLCIIndexValue,
frLportTypeAdmin,
frLportVCSigProtocolAdmin }
STATUS current
DESCRIPTION
"Administrative (R/W) objects for creating a
switch logical port."
::= { frnetservGroups 10 }
frnetservMgtVCSigAdminGroup OBJECT-GROUP
OBJECTS { frMgtVCSigProcedAdmin,
frMgtVCSigUserN391Admin,
frMgtVCSigUserN392Admin,
frMgtVCSigUserN393Admin,
frMgtVCSigUserT391Admin,
frMgtVCSigNetN392Admin,
frMgtVCSigNetN393Admin,
frMgtVCSigNetT392Admin,
frMgtVCSigNetnT3Admin }
STATUS current
DESCRIPTION
"A collection of objects providing information
applicable to the Local In-Channel Signaling
Procedures used for a UNI/NNI logical port."
::= { frnetservGroups 11 }
frnetservPVCNotifGroup NOTIFICATION-GROUP
NOTIFICATIONS { frPVCConnectStatusChange }
STATUS deprecated
DESCRIPTION
"Deprecated notification group. The
frPVCConnectStatusChange notification was flawed
because it included redundant indexes and was not
properly encoded for SMIv1 conversion."
::= { frnetservGroups 12 }
frnetservPVCNotifGroup2 NOTIFICATION-GROUP
NOTIFICATIONS { frPVCConnectStatusNotif }
STATUS current
DESCRIPTION
"A collection of notifications that apply to frame
relay PVC Connections "
::= { frnetservGroups 13 }
END
ACC SHELL 2018