ACC SHELL
ROHC-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Unsigned32, Counter32, mib-2
FROM SNMPv2-SMI -- [RFC2578]
TEXTUAL-CONVENTION, TruthValue,
TimeInterval, DateAndTime
FROM SNMPv2-TC -- [RFC2579]
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF -- [RFC2580]
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB -- [RFC3411]
ifIndex
FROM IF-MIB; -- [RFC2863]
rohcMIB MODULE-IDENTITY
LAST-UPDATED "200406030000Z" -- June 3, 2004
ORGANIZATION "IETF Robust Header Compression Working Group"
CONTACT-INFO
"WG charter:
http://www.ietf.org/html.charters/rohc-charter.html
Mailing Lists:
General Discussion: rohc@ietf.org
To Subscribe: rohc-request@ietf.org
In Body: subscribe your_email_address
Editor:
Juergen Quittek
NEC Europe Ltd.
Network Laboratories
Kurfuersten-Anlage 36
69221 Heidelberg
Germany
Tel: +49 6221 90511-15
EMail: quittek@netlab.nec.de"
DESCRIPTION
"This MIB module defines a set of basic objects for
monitoring and configuring robust header compression.
The module covers information about running instances
of ROHC (compressors or decompressors) at IP interfaces.
Information about compressor contexts and decompressor
contexts has different structure for different profiles.
Therefore it is not provided by this MIB module, but by
individual modules for different profiles.
Copyright (C) The Internet Society (2004). The
initial version of this MIB module was published
in RFC 3816. For full legal notices see the RFC
itself or see:
http://www.ietf.org/copyrights/ianamib.html"
REVISION "200406030000Z" -- June 3, 2004
DESCRIPTION "Initial version, published as RFC 3816."
::= { mib-2 112 }
RohcChannelIdentifier ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"A number identifying a channel.
The value of 0 must not be used as identifier
of an existing channel."
SYNTAX Unsigned32 (1..4294967295)
RohcChannelIdentifierOrZero ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"A number identifying a channel.
The value of 0 is indicates that
no channel is identified."
SYNTAX Unsigned32 (0..4294967295)
RohcCompressionRatio ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"A number indicating a compression ratio over
a set of bytes. The value is defined as
1000 * bytes(compressed) / bytes(original)
rounded to the next integer value.
Note that compressed sets of bytes can be larger
than the corresponding uncompressed ones.
Therefore, the number can be greater than 1000."
SYNTAX Unsigned32
--
-- The groups defined within this MIB module:
--
rohcObjects OBJECT IDENTIFIER ::= { rohcMIB 1 }
rohcConformance OBJECT IDENTIFIER ::= { rohcMIB 2 }
--
-- The ROHC Instance group lists properties of ROHC
-- instances in the rohcInstanceTable, about the channels used
-- by the instances in the rohcChanneltable and about the profiles
-- available at the instances in the rohcProfileTable.
--
rohcInstanceObjects OBJECT IDENTIFIER ::= { rohcObjects 1 }
--
-- Channel Table
--
-- Listing all channels used for ROHC data channel
-- and/or as feedback channel.
--
rohcChannelTable OBJECT-TYPE
SYNTAX SEQUENCE OF RohcChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists and describes all ROHC channels
per interface."
::= { rohcInstanceObjects 1 }
rohcChannelEntry OBJECT-TYPE
SYNTAX RohcChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry describing a particular script. Every script that
is stored in non-volatile memory is required to appear in
this script table.
Note, that the rohcChannelID identifies the channel
uniquely. The ifIndex is part of the index of this table
just in order to allow addressing channels per interface."
INDEX { ifIndex, rohcChannelID }
::= { rohcChannelTable 1 }
RohcChannelEntry ::= SEQUENCE {
rohcChannelID RohcChannelIdentifier,
rohcChannelType INTEGER,
rohcChannelFeedbackFor RohcChannelIdentifierOrZero,
rohcChannelDescr SnmpAdminString,
rohcChannelStatus INTEGER
}
rohcChannelID OBJECT-TYPE
SYNTAX RohcChannelIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The locally arbitrary, but unique identifier associated
with this channel. The value is REQUIRED to be unique
per ROHC MIB implementation independent of the associated
interface.
The value is REQUIRED to remain constant at least from one
re-initialization of the entity's network management system
to the next re-initialization. It is RECOMMENDED that the
value persist across such re-initializations."
REFERENCE
"RFC 3095, Section 5.1.1"
::= { rohcChannelEntry 2 }
rohcChannelType OBJECT-TYPE
SYNTAX INTEGER {
notInUse(1),
rohc(2),
dedicatedFeedback(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type of usage of the channel. A channel might be currently
not in use for ROHC or feedback, it might be in use as
a ROHC channel carrying packets and optional piggy-backed
feedback, or it might be used as a dedicated feedback
channel exclusively carrying feedback."
::= { rohcChannelEntry 3 }
rohcChannelFeedbackFor OBJECT-TYPE
SYNTAX RohcChannelIdentifierOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of another channel of this interface for which
the channel serves as feedback channel.
If no feedback information is transferred on this channel,
then the value of this ID is 0. If the channel type is set
to notInUse(1), then the value of this object must be 0.
If the channel type is rohc(2) and the value of this object
is a valid channel ID, then feedback information is
piggy-backed on the ROHC channel. If the channel type is
dedicatedFeedback(3), then feedback is transferred on this
channel and the value of this object MUST be different from
0 and MUST identify an existing ROHC channel."
REFERENCE
"RFC 3095, Section 5.1.1"
::= { rohcChannelEntry 4 }
rohcChannelDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual description of the channel."
::= { rohcChannelEntry 5 }
rohcChannelStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the channel."
::= { rohcChannelEntry 6 }
--
-- Instances of ROHC
--
-- This table lists properties of running instances of ROHC
-- compressors and decompressors at the managed node.
--
rohcInstanceTable OBJECT-TYPE
SYNTAX SEQUENCE OF RohcInstanceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists properties of running instances
of robust header compressors and decompressors
at IP interfaces. It is indexed by interface number,
the type of instance (compressor or decompressor),
and the ID of the channel used by the instance as
ROHC channel.
Note that the rohcChannelID uniquely identifies an
instance. The ifIndex and rohcInstanceType are part
of the index, because it simplifies accessing instances
per interface and for addressing either compressors or
decompressors only."
::= { rohcInstanceObjects 2 }
rohcInstanceEntry OBJECT-TYPE
SYNTAX RohcInstanceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry describing a particular instance
of a robust header compressor or decompressor."
INDEX { ifIndex, rohcInstanceType, rohcChannelID }
::= { rohcInstanceTable 1 }
RohcInstanceEntry ::= SEQUENCE {
rohcInstanceType INTEGER,
rohcInstanceFBChannelID RohcChannelIdentifierOrZero,
rohcInstanceVendor OBJECT IDENTIFIER,
rohcInstanceVersion SnmpAdminString,
rohcInstanceDescr SnmpAdminString,
rohcInstanceClockRes Unsigned32,
rohcInstanceMaxCID Unsigned32,
rohcInstanceLargeCIDs TruthValue,
rohcInstanceMRRU Unsigned32,
rohcInstanceContextStorageTime TimeInterval,
rohcInstanceStatus INTEGER,
rohcInstanceContextsTotal Counter32,
rohcInstanceContextsCurrent Unsigned32,
rohcInstancePackets Counter32,
rohcInstanceIRs Counter32,
rohcInstanceIRDYNs Counter32,
rohcInstanceFeedbacks Counter32,
rohcInstanceCompressionRatio RohcCompressionRatio
}
rohcInstanceType OBJECT-TYPE
SYNTAX INTEGER {
compressor(1),
decompressor(2)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Type of the instance of ROHC. It is either a
compressor instance or a decompressor instance."
::= { rohcInstanceEntry 2 }
rohcInstanceFBChannelID OBJECT-TYPE
SYNTAX RohcChannelIdentifierOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifier of the channel used for feedback.
If no feedback channel is used, the value of
this object is 0 ."
REFERENCE
"RFC 3095, Section 5.1.1"
::= { rohcInstanceEntry 4 }
rohcInstanceVendor OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An object identifier that identifies the vendor who
provides the implementation of robust header description.
This object identifier SHALL point to the object identifier
directly below the enterprise object identifier
{1 3 6 1 4 1} allocated for the vendor. The value must be
the object identifier {0 0} if the vendor is not known."
::= { rohcInstanceEntry 5 }
rohcInstanceVersion OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version number of the implementation of robust header
compression. The zero-length string shall be used if the
implementation does not have a version number.
It is suggested that the version number consist of one or
more decimal numbers separated by dots, where the first
number is called the major version number."
::= { rohcInstanceEntry 6 }
rohcInstanceDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual description of the implementation."
::= { rohcInstanceEntry 7 }
rohcInstanceClockRes OBJECT-TYPE
SYNTAX Unsigned32
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the system clock resolution in
units of milliseconds. A zero (0) value means that there
is no clock available."
::= { rohcInstanceEntry 8 }
rohcInstanceMaxCID OBJECT-TYPE
SYNTAX Unsigned32 (1..16383)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest context ID number to be used by the
compressor. Note that this parameter is not coupled to,
but in effect further constrained by,
rohcChannelLargeCIDs."
REFERENCE
"RFC 3095, Section 5.1.1"
::= { rohcInstanceEntry 9 }
rohcInstanceLargeCIDs OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When retrieved, this boolean object returns false if
the short CID representation (0 bytes or 1 prefix byte,
covering CID 0 to 15) is used; it returns true, if the
embedded CID representation (1 or 2 embedded CID bytes
covering CID 0 to 16383) is used."
REFERENCE
"RFC 3095, Section 5.1.1"
::= { rohcInstanceEntry 10 }
rohcInstanceMRRU OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum reconstructed reception unit. This is the
size of the largest reconstructed unit in octets that
the decompressor is expected to reassemble from
segments (see RFC 3095, Section 5.2.5). Note that this
size includes the CRC. If MRRU is negotiated to be 0,
no segment headers are allowed on the channel."
REFERENCE
"RFC 3095, Section 5.1.1"
::= { rohcInstanceEntry 11 }
rohcInstanceContextStorageTime OBJECT-TYPE
SYNTAX TimeInterval
UNITS "centi-seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the default maximum amount of time
information on a context belonging to this instance is kept
as entry in the rohcContextTable after the context is
expired or terminated. The value of this object is used
to initialize rohcContexStorageTime object when a new
context is created.
Changing the value of an rohcInstanceContextStorageTime
instance does not affect any entry of the rohcContextTable
created previously.
ROHC-MIB implementations SHOULD store the set value of this
object persistently."
DEFVAL { 360000 }
::= { rohcInstanceEntry 12 }
rohcInstanceStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the instance of ROHC."
::= { rohcInstanceEntry 13 }
rohcInstanceContextsTotal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Counter of all contexts created by this instance.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime."
::= { rohcInstanceEntry 14 }
rohcInstanceContextsCurrent OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of currently active contexts created by this
instance."
::= { rohcInstanceEntry 15 }
rohcInstancePackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Counter of all packets passing this instance.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime."
::= { rohcInstanceEntry 16 }
rohcInstanceIRs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of all IR packets that are either sent
or received by this instance.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE
"RFC 3095, Section 5.7.7.1"
::= { rohcInstanceEntry 17 }
rohcInstanceIRDYNs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of all IR-DYN packets that are either sent
or received by this instance.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE
"RFC 3095, Section 5.7.7.2"
::= { rohcInstanceEntry 18 }
rohcInstanceFeedbacks OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of all feedbacks that are either sent
or received by this instance.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime."
::= { rohcInstanceEntry 19 }
rohcInstanceCompressionRatio OBJECT-TYPE
SYNTAX RohcCompressionRatio
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the compression ratio so far over all
packets on the channel served by this instance. The
compression is computed over all bytes of the IP packets
including the IP header but excluding all lower layer
headers."
::= { rohcInstanceEntry 20 }
--
-- Profile Table
--
rohcProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF RohcProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists a set of profiles supported by the
instance."
REFERENCE
"RFC 3095, Section 5.1.1"
::= { rohcInstanceObjects 3 }
rohcProfileEntry OBJECT-TYPE
SYNTAX RohcProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry describing a particular profile supported by
the instance. It is indexed by the rohcChannelID
identifying the instance and by the rohcProfile."
INDEX { rohcChannelID, rohcProfile }
::= { rohcProfileTable 1 }
RohcProfileEntry ::= SEQUENCE {
rohcProfile Unsigned32,
rohcProfileVendor OBJECT IDENTIFIER,
rohcProfileVersion SnmpAdminString,
rohcProfileDescr SnmpAdminString,
rohcProfileNegotiated TruthValue
}
rohcProfile OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identifier of a profile supported. For a listing of
possible profile values, see the IANA registry for
'RObust Header Compression (ROHC) Profile Identifiers'
at http://www.iana.org/assignments/rohc-pro-ids"
::= { rohcProfileEntry 2 }
rohcProfileVendor OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An object identifier that identifies the vendor who
provides the implementation of robust header description.
This object identifier SHALL point to the object identifier
directly below the enterprise object identifier
{1 3 6 1 4 1} allocated for the vendor. The value must be
the object identifier {0 0} if the vendor is not known."
::= { rohcProfileEntry 3 }
rohcProfileVersion OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version number of the implementation of robust header
compression. The zero-length string shall be used if the
implementation does not have a version number.
It is suggested that the version number consist of one or
more decimal numbers separated by dots, where the first
number is called the major version number."
::= { rohcProfileEntry 4 }
rohcProfileDescr OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual description of the implementation."
::= { rohcProfileEntry 5 }
rohcProfileNegotiated OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When retrieved, this boolean object returns true
if the profile has been negotiated to be used at
the instance, i.e., is supported also be the
corresponding compressor/decompressor."
::= { rohcProfileEntry 6 }
--
-- Context Table
--
rohcContextTable OBJECT-TYPE
SYNTAX SEQUENCE OF RohcContextEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists and describes all compressor contexts
per instance."
::= { rohcObjects 2 }
rohcContextEntry OBJECT-TYPE
SYNTAX RohcContextEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry describing a particular compressor context."
INDEX {
rohcChannelID,
rohcContextCID
}
::= { rohcContextTable 1 }
RohcContextEntry ::= SEQUENCE {
rohcContextCID Unsigned32,
rohcContextCIDState INTEGER,
rohcContextProfile Unsigned32,
rohcContextDecompressorDepth Unsigned32,
rohcContextStorageTime TimeInterval,
rohcContextActivationTime DateAndTime,
rohcContextDeactivationTime DateAndTime,
rohcContextPackets Counter32,
rohcContextIRs Counter32,
rohcContextIRDYNs Counter32,
rohcContextFeedbacks Counter32,
rohcContextDecompressorFailures Counter32,
rohcContextDecompressorRepairs Counter32,
rohcContextAllPacketsRatio RohcCompressionRatio,
rohcContextAllHeadersRatio RohcCompressionRatio,
rohcContextAllPacketsMeanSize Unsigned32,
rohcContextAllHeadersMeanSize Unsigned32,
rohcContextLastPacketsRatio RohcCompressionRatio,
rohcContextLastHeadersRatio RohcCompressionRatio,
rohcContextLastPacketsMeanSize Unsigned32,
rohcContextLastHeadersMeanSize Unsigned32
}
rohcContextCID OBJECT-TYPE
SYNTAX Unsigned32 (0..16383)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The context identifier (CID) of this context."
REFERENCE
"RFC 3095, Sections 5.1.1 and 5.1.3"
::= { rohcContextEntry 2 }
rohcContextCIDState OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
active(2),
expired(3),
terminated(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the CID. When a CID is assigned to a context,
its state changes from `unused' to `active'. The active
context may stop operation due to some explicit
signalling or after observing no packet for some specified
time. In the first case then the CID state changes to
`terminated', in the latter case it changes to `expired'.
If the CID is re-used again for another context, the
state changes back to `active'."
::= { rohcContextEntry 3 }
rohcContextProfile OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifier of the profile for this context.
The profile is identified by its index in the
rohcProfileTable for this instance. There MUST exist a
corresponding entry in the rohcProfileTable using the
value of rohcContextProfile as second part of the index
(and using the same rohcChannelID as first part of the
index)."
::= { rohcContextEntry 4 }
rohcContextDecompressorDepth OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates whether reverse decompression, for
example as described in RFC 3095, Section 6.1, is used
on this channel or not, and if used, to what extent.
Its value is only valid for decompressor contexts, i.e.,
if rohcInstanceType has the value decompressor(2). For
compressor contexts where rohcInstanceType has the value
compressor(1), the value of this object is irrelevant
and MUST be set to zero (0).
The value of the reverse decompression depth indicates
the maximum number of packets that are buffered, and thus
possibly be reverse decompressed by the decompressor.
A zero (0) value means that reverse decompression is not
used."
::= { rohcContextEntry 5 }
rohcContextStorageTime OBJECT-TYPE
SYNTAX TimeInterval
UNITS "centi-seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this object specifies how long this row
can exist in the rohcContextTable after the
rohcContextCIDState switched to expired(3) or
terminated(4). This object returns the remaining time
that the row may exist before it is aged out. The object
is initialized with the value of the associated
rohcContextStorageTime object. After expiration or
termination of the context, the value of this object ticks
backwards. The entry in the rohcContextTable is destroyed
when the value reaches 0.
The value of this object may be set in order to increase or
reduce the remaining time that the row may exist. Setting
the value to 0 will destroy this entry as soon as the
rochContextCIDState has the value expired(3) or
terminated(4).
Note that there is no guarantee that the row is stored as
long as this object indicates. In case of limited CID
space, the instance may re-use a CID before the storage
time of the corresponding row in rohcContextTable reaches
the value of 0. In this case the information stored in this
row is not anymore available."
::= { rohcContextEntry 6 }
rohcContextActivationTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date and time when the context started to be able to
compress packets or decompress packets, respectively.
The value '0000000000000000'H is returned if the context
has not been activated yet."
DEFVAL { '0000000000000000'H }
::= { rohcContextEntry 7 }
rohcContextDeactivationTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date and time when the context stopped being able to
compress packets or decompress packets, respectively,
because it expired or was terminated for other reasons.
The value '0000000000000000'H is returned if the context
has not been deactivated yet."
DEFVAL { '0000000000000000'H }
::= { rohcContextEntry 8 }
rohcContextPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of all packets passing this context.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime. For checking
ifCounterDiscontinuityTime, the interface index is
required. It can be determined by reading the
rohcChannelTable."
::= { rohcContextEntry 9 }
rohcContextIRs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of all IR packets sent or received,
respectively, by this context.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime. For checking
ifCounterDiscontinuityTime, the interface index is
required. It can be determined by reading the
rohcChannelTable."
REFERENCE
"RFC 3095, Section 5.7.7.1"
::= { rohcContextEntry 10 }
rohcContextIRDYNs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of all IR-DYN packets sent or received,
respectively, by this context.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime. For checking
ifCounterDiscontinuityTime, the interface index is
required. It can be determined by reading the
rohcChannelTable."
REFERENCE
"RFC 3095, Section 5.7.7.2"
::= { rohcContextEntry 11 }
rohcContextFeedbacks OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of all feedbacks sent or received,
respectively, by this context.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime. For checking
ifCounterDiscontinuityTime, the interface index is
required. It can be determined by reading the
rohcChannelTable."
::= { rohcContextEntry 12 }
rohcContextDecompressorFailures OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of all decompressor failures so far in this
context. The number is only valid for decompressor
contexts, i.e., if rohcInstanceType has the value
decompressor(2).
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime. For checking
ifCounterDiscontinuityTime, the interface index is
required. It can be determined by reading the
rohcChannelTable."
::= { rohcContextEntry 13 }
rohcContextDecompressorRepairs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of all context repairs so far in this
context. The number is only valid for decompressor
contexts, i.e., if rohcInstanceType has the value
decompressor(2).
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime. For checking
ifCounterDiscontinuityTime, the interface index is
required. It can be determined by reading the
rohcChannelTable."
::= { rohcContextEntry 14 }
rohcContextAllPacketsRatio OBJECT-TYPE
SYNTAX RohcCompressionRatio
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the compression ratio so far over all
packets passing this context. The compression is computed
over all bytes of the IP packets including the IP header
but excluding all lower layer headers."
::= { rohcContextEntry 15 }
rohcContextAllHeadersRatio OBJECT-TYPE
SYNTAX RohcCompressionRatio
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the compression ratio so far over all
packet headers passing this context. The compression is
computed over all bytes of all headers that are subject to
compression for the used profile."
::= { rohcContextEntry 16 }
rohcContextAllPacketsMeanSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the mean compressed packet size
of all packets passing this context. The packet size
includes the IP header and payload but excludes all lower
layer headers. The mean value is given in byte rounded
to the next integer value."
::= { rohcContextEntry 17 }
rohcContextAllHeadersMeanSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the mean compressed packet header size
of all packets passing this context. The packet header size
is the sum of the size of all headers of a packet that are
subject to compression for the used profile. The mean value
is given in byte rounded to the next integer value."
::= { rohcContextEntry 18 }
rohcContextLastPacketsRatio OBJECT-TYPE
SYNTAX RohcCompressionRatio
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the compression ratio
concerning the last 16 packets passing this context
or concerning all packets passing this context
if they are less than 16, so far. The compression is
computed over all bytes of the IP packets including the IP
header but excluding all lower layer headers."
::= { rohcContextEntry 19 }
rohcContextLastHeadersRatio OBJECT-TYPE
SYNTAX RohcCompressionRatio
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the compression ratio concerning the
headers of the last 16 packets passing this context or
concerning the headers of all packets passing this context
if they are less than 16, so far. The compression is
computed over all bytes of all headers that are subject to
compression for the used profile."
::= { rohcContextEntry 20 }
rohcContextLastPacketsMeanSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the mean compressed packet size
concerning the last 16 packets passing this context or
concerning all packets passing this context if they are
less than 16, so far. The packet size includes the IP
header and payload but excludes all lower layer headers.
The mean value is given in byte rounded to the next
integer value."
::= { rohcContextEntry 21 }
rohcContextLastHeadersMeanSize OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the mean compressed packet header size
concerning the last 16 packets passing this context or
concerning all packets passing this context if they are
less than 16, so far. The packet header size is the sum of
the size of all headers of a packet that are subject to
compression for the used profile. The mean value is given
in byte rounded to the next integer value."
::= { rohcContextEntry 22 }
--
-- conformance information
--
rohcCompliances OBJECT IDENTIFIER ::= { rohcConformance 1 }
rohcGroups OBJECT IDENTIFIER ::= { rohcConformance 2 }
--
-- compliance statements
--
rohcCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMP entities that implement
the ROHC-MIB.
Note that compliance with this compliance
statement requires compliance with the
ifCompliance3 MODULE-COMPLIANCE statement of the
IF-MIB (RFC2863)."
MODULE -- this module
MANDATORY-GROUPS {
rohcInstanceGroup, rohcContextGroup
}
GROUP rohcStatisticsGroup
DESCRIPTION
"A compliant implementation does not have to implement
the rohcStatisticsGroup."
GROUP rohcTimerGroup
DESCRIPTION
"A compliant implementation does not have to implement
the rohcTimerGroup."
OBJECT rohcInstanceContextStorageTime
MIN-ACCESS read-only
DESCRIPTION
"A compliant implementation does not have to support changing
the value of object rohcInstanceContextStorageTime."
OBJECT rohcContextStorageTime
MIN-ACCESS read-only
DESCRIPTION
"A compliant implementation does not have to support changing
the value of object rohcContextStorageTime."
GROUP rohcContextStatisticsGroup
DESCRIPTION
"A compliant implementation does not have to implement
the rohcContextStatisticsGroup."
::= { rohcCompliances 1 }
rohcInstanceGroup OBJECT-GROUP
OBJECTS {
rohcChannelType,
rohcChannelFeedbackFor,
rohcChannelDescr,
rohcChannelStatus,
rohcInstanceFBChannelID,
rohcInstanceVendor,
rohcInstanceVersion,
rohcInstanceDescr,
rohcInstanceClockRes,
rohcInstanceMaxCID,
rohcInstanceLargeCIDs,
rohcInstanceMRRU,
rohcInstanceStatus,
rohcProfileVendor,
rohcProfileVersion,
rohcProfileDescr,
rohcProfileNegotiated
}
STATUS current
DESCRIPTION
"A collection of objects providing information about
ROHC instances, used channels and available profiles."
::= { rohcGroups 2 }
rohcStatisticsGroup OBJECT-GROUP
OBJECTS {
rohcInstanceContextsTotal,
rohcInstanceContextsCurrent,
rohcInstancePackets,
rohcInstanceIRs,
rohcInstanceIRDYNs,
rohcInstanceFeedbacks,
rohcInstanceCompressionRatio
}
STATUS current
DESCRIPTION
"A collection of objects providing ROHC statistics."
::= { rohcGroups 4 }
rohcContextGroup OBJECT-GROUP
OBJECTS {
rohcContextCIDState,
rohcContextProfile,
rohcContextDecompressorDepth
}
STATUS current
DESCRIPTION
"A collection of objects providing information about
ROHC compressor contexts and decompressor contexts."
::= { rohcGroups 5 }
rohcTimerGroup OBJECT-GROUP
OBJECTS {
rohcInstanceContextStorageTime,
rohcContextStorageTime,
rohcContextActivationTime,
rohcContextDeactivationTime
}
STATUS current
DESCRIPTION
"A collection of objects providing statistical information
about ROHC compressor contexts and decompressor contexts."
::= { rohcGroups 6 }
rohcContextStatisticsGroup OBJECT-GROUP
OBJECTS {
rohcContextPackets,
rohcContextIRs,
rohcContextIRDYNs,
rohcContextFeedbacks,
rohcContextDecompressorFailures,
rohcContextDecompressorRepairs,
rohcContextAllPacketsRatio,
rohcContextAllHeadersRatio,
rohcContextAllPacketsMeanSize,
rohcContextAllHeadersMeanSize,
rohcContextLastPacketsRatio,
rohcContextLastHeadersRatio,
rohcContextLastPacketsMeanSize,
rohcContextLastHeadersMeanSize
}
STATUS current
DESCRIPTION
"A collection of objects providing statistical information
about ROHC compressor contexts and decompressor contexts."
::= { rohcGroups 7 }
END